Product Details | VOLTMETER

6625-00-422-3241 An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

Part Alternates: 4130356, 413-0356 , 931B01, 931B-01, 6625-00-422-3241, 00-422-3241, 6625004223241, 004223241

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 09 FEB 1972 00-422-3241

Drawings & Photos | NSN 6625-00-422-3241


Cross Reference | NSN 6625-00-422-3241

Part Number Cage Code Manufacturer
931B-01 K6022 FLUKE UK LTD
931B01 89536 FLUKE CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-422-3241

Technical Data | NSN 6625-00-422-3241

Characteristic Specifications
INSTALLATION DESIGN HAND HELD
(NON-CORE DATA) CIRCUIT CONSTRUCTION TYPE ELECTRONIC, SOLID STATE
INDICATOR TYPE DIAL W/POINTER
MEASUREMENT RANGE 0.01 TO 1100.00 MEGAHERTZ SINGLE INDICATOR SINGLE RANGE
ACCURACY IN PERCENT -0.05 TO 0.05 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
SCALE GRADUATION TYPE NONLINEAR SINGLE INDICATOR SINGLE RANGE
POINTER COLOR BLACK SINGLE INDICATOR SINGLE RANGE
DIAL SCALE MARKING COLOR BLACK SINGLE INDICATOR SINGLE RANGE
FREQUENCY RESPONSE RANGE 0.000 TO 2.000 MEGAHERTZ
CIRCUIT CURRENT FOR WHICH DESIGNED AC AND DC
OPERATING VOLTAGE RATING IN VOLTS 115.0 AC MINIMUM AND 230.0 AC MAXIMUM
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM
STYLE DESIGNATOR D1 RECTANGULAR OR SQUARE
OVERALL HEIGHT 7.000 INCHES NOMINAL
OVERALL LENGTH 11.750 INCHES NOMINAL
OVERALL WIDTH 8.500 INCHES NOMINAL
NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED
MANUFACTURERS CODE 89536
DESIGN CONTROL REFERENCE 931B01

Restrictions/Controls & Freight Information | NSN 6625-00-422-3241

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating D 200
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-00-422-3241

Category Code Description
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilitySAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Stores Account Code2Marine Corps Appropriation Stores Account Secondary Items.
Combat Essentiality Code2Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items.
Materiel Management Code4Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplyMPBCommanding General
Marine Corps Logistics Command
566-2, Bldg. 3700
Albany, GA 31704-5000
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityDReparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes7ZGeneral purpose electronic test equipment to support various Naval Systems Commands equipment/programs.
Naval Inventory Control Point, Mechanicsburg
Special Material IDTEGeneral purpose electronic test equipment
Issue Repair, or RequisitionBLSubmit/refer requisitions to NAVICP MECH. Centralized control for issue of repair parts for specific programs/equipments.
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplyN35Naval Inventory Control Point
Mechanicsburg, PA 17055-0788
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityHDepot Level Reparable
Acquisition Advice CodesCSERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each