Product Details | FREQUENCY STANDARD

6625-00-829-0911 An item that can generate a fundamental frequency with a high degree of accuracy. Harmonics of this fundamental are then used as a reference point for checking throughout the radio spectrum. The standard may be stable crystal oscillator, noncrystal oscillator, tuning fork, atomic beam, molecular beam, gas cell, quantum mechanical resonator, or the like.

Part Alternates: E205060A, E20-5060A, 5060AE20, 5060A-E20, 6625-00-829-0911, 00-829-0911, 6625008290911, 008290911

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 30 AUG 1967 00-829-0911

Cross Reference | NSN 6625-00-829-0911

Part Number Cage Code Manufacturer
5060A-E20 1LQK8 KEYSIGHT TECHNOLOGIES, INC.
5060A-E20 1MY97 AGILENT TECHNOLOGIES, INC. DIV AGILENT TECHNOLOGIES
5060A-E20 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP
E20-5060A 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-829-0911

Technical Data | NSN 6625-00-829-0911

Characteristic Specifications
UNIT TYPE STANDARD
FREQUENCY RANGE RATING 0.001 TO 100.000 KILOHERTZ
PLUG-IN UNIT QUANTITY 0
INDIVIDUAL PLUG-IN UNIT FREQUENCY NOT RATED
AC VOLTAGE RATING 115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 1000.0 HERTZ MAXIMUM
DC VOLTAGE RATING 22.0 VOLTS MINIMUM AND 30.0 VOLTS MAXIMUM
OVERALL WIDTH 16.750 INCHES NOMINAL
OVERALL HEIGHT 8.750 INCHES NOMINAL
OVERALL DEPTH 16.375 INCHES NOMINAL
MOUNTING METHOD BENCH
RECORDING DEVICE ACCOMMODATION NOT PROVIDED
SPECIAL FEATURES CESIUM BEAM 133
III UNPACKAGED UNIT WEIGHT 63.000 POUNDS
III SUPPLEMENTARY FEATURES CESIUM BEAM STANDARD
III REFERENCE DATA AND LITERATURE T.O.33A1-5-318-1

Restrictions/Controls & Freight Information | NSN 6625-00-829-0911

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating D 200
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-00-829-0911

Category Code Description
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Source of SupplyJCD
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each