Product Details | SPECTRUM ANALYZER

6625-00-845-7183 An instrument specifically designed to measure the amplitude and frequency of the constituents of a complex electrical wave form. May include transducer mechanism for converting sound pressure into electrical energy.

Part Alternates: TS-1830/U, TS1830U, 736A, 7907320, 02-268522-1, 302AR, 6552163, 6625-00-845-7183, 00-845-7183, 6625008457183, 022685221, 008457183

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 1962 00-845-7183

Demand History | NSN 6625-00-845-7183

Part Number Request Date QTY Origin
736A 2010-09-250 6 United States
6625-00-845-7183 2009-01-03 5 India

Cross Reference | NSN 6625-00-845-7183

Part Number Cage Code Manufacturer
02-268522-1 04655 GENERAL DYNAMICS C4 SYSTEMS, INC.
302AR 1LQK8 KEYSIGHT TECHNOLOGIES, INC.
302AR 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP
6552163 03640 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
6552163 0B6S1 INTERNATIONAL BUSINESS MACHINES CORP PARTS ORDER CENTER DEPT E - 54
6552163 30874 INTERNATIONAL BUSINESS MACHINES CORP
736A 24655 GENRAD INC
7907320 18876 U S ARMY AVIATION AND MISSILE COMMAND
TS-1830/U 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-845-7183

Technical Data | NSN 6625-00-845-7183

Characteristic Specifications
UNIT TYPE STANDARD
FREQUENCY RANGE RATING 0.020 TO 50.000 KILOHERTZ
INDIVIDUAL PLUG-IN UNIT FREQUENCY NOT RATED
FREQUENCY BAND QUANTITY 1
FREQUENCY CALIBRATION ACCURACY RANGE IN PERCENT -1.0 TO 1.0
METER SCALE RANGE 3 UV TO 300 V FULL
METER ACCURACY RANGE IN PERCENT -5.0 TO 5.0
INPUT IMPEDANCE RATING 1.0 MEGOHMS NOMINAL
AC VOLTAGE RATING 115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM
FREQUENCY RATING 0.05 KILOHERTZ MINIMUM AND 1.6 KILOHERTZ MAXIMUM
PHASE SINGLE
DC VOLTAGE RATING 28.0 VOLTS NOMINAL
OVERALL LENGTH 20.750 INCHES NOMINAL
OVERALL WIDTH 14.500 INCHES NOMINAL
OVERALL DEPTH 12.500 INCHES NOMINAL
RECORDING DEVICE ACCOMMODATION NOT PROVIDED
III REFERENCE DATA AND LITERATURE TO 33A1-13-259-4
MANUFACTURERS CODE 1LQK8
DESIGN CONTROL REFERENCE 302AR

Restrictions/Controls & Freight Information | NSN 6625-00-845-7183

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-00-845-7183

Category Code Description
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilitySAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code2Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items.
Materiel Management Code4Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665
Echelon Management Code9ICP Weapon system-oriented consumable items assigned to Marine Corps for integrated materiel management and which are managed by the ICP on a system-wide basis.
Echelon Identification CodeAType 1 End Items 1
Operational Test Code2Items of equipment which require the performance of special procedures are not controlled through the MOWASP special handling suspense routine by USMC/Serial Numbers, (except small arms which are controlled by serial numbers but are assigned OTC 2). Normally OTC 2 items of equipments are small arms, engines (except small engines coded SAC-1 which are non-technical), pumps, generators, electronic equipments and major components/subassemblies of weapon systems, etc. Electronic Circuit Cards and other items which have received Level A packing will only be assigned an OTC when an operational test is mandatory prior to issue.
Source of SupplyMPBCommanding General
Marine Corps Logistics Command
566-2, Bldg. 3700
Albany, GA 31704-5000
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityHReparable item. When uneconomically reparable, condemn and dispose at fourth echelon level.
Acquisition Advice CodesNRESTRICTED REQUISITIONING-DISPOSAL (Service/Agency use only.) # Discontinued items no longer authorized for issue except on the specific approval of the Service inventory manager. Requisitions may be submitted in accordance with Service requisitioning procedures in instances where valid requirements exist and replacing item data has not been furnished.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes1RAeronautical, photographic, and meteorological material (consumable or expense type material)
Naval Inventory Control Point, Philadelphia
Issue Repair, or RequisitionC0Critical item. Do not issue. Refer all requests to cognizant manager.
Source of SupplyN32Naval Inventory Control Point
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityDField Level Reparables
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each