Product Details | PULSE GENERATOR

6625-00-905-9096 An electronic device which develops a discontinuous electrical potential with an abrupt rate of change of voltage which determines the harmonic content of the pulse train. The duration of a single pulse output is relatively short compared to the time of the recurrence cycle. See also GENERATOR, SINGLE PULSE; and GENERATOR, ELECTRONIC MARKER.20358950037Miscellaneous Communication Equipment61150041Generators and Generator Sets, Electrical66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: A10760000, ANUPM55B, 96001, 96-001, 6625-00-905-9096, 00-905-9096, 6625009059096, 009059096

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 1960 00-905-9096

Drawings & Photos | NSN 6625-00-905-9096


Cross Reference | NSN 6625-00-905-9096

Part Number Cage Code Manufacturer
96-001 02048 RADIATION INSTRUMENT DEVELOPMENT
A10760000 99872 ENTRON INDUSTRIES LIMITED PARTNERSHIP
ANUPM55B 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-905-9096

Technical Data | NSN 6625-00-905-9096

Characteristic Specifications
FREQUENCY PER CHANNEL 20.0 HERTZ MINIMUM OPERATING CHANNEL 20.0 KILOHERTZ MAXIMUM OPERATING CHANNEL
ATTENUATION IN DECIBELS NOT RATED
AVERAGE POWER RATING PER CHANNEL NOT RATED
SIGNAL VOLTAGE RATING PER CHANNEL NOT RATED
OVERALL GAIN NOT RATED
IMPEDANCE RATING PER CHANNEL 600.000 OHMS 1ST OUTPUT CHANNEL 5.000 KILOHMS 2ND OUTPUT CHANNEL 5.000 KILOHMS 3RD OUTPUT CHANNEL
PULSE PEAK AMPLITUDE PER CHANNEL 5.000 VOLTS 1ST OUTPUT CHANNEL 45.000 VOLTS 2ND OUTPUT CHANNEL 45.000 VOLTS 3RD OUTPUT CHANNEL
PULSE DURATION PER CHANNEL 200.000 NANOSECONDS MINIMUM 1ST OUTPUT CHANNEL 20.000 MICROSECONDS MAXIMUM 1ST OUTPUT CHANNEL 400.000 NANOSECONDS MINIMUM 2ND OUTPUT CHANNEL 1.000 MICROSECONDS MAXIMUM 2ND OUTPUT CHANNEL
POLARITY PER CHANNEL NEGATIVE OR POSITIVE POLARITY ALL OUTPUTCHANNELS
PULSE REPETITION RATE PER CHANNEL 20.0 PULSES TO 20.0 KILOPULSE REPETITION RATE ALL CHANNELS
PULSE MODULATION TYPE PER CHANNEL AMPLITUDE 1ST OUTPUT CHANNEL AMPLITUDE 2ND OUTPUT CHANNEL AMPLITUDE 3RD OUTPUT CHANNEL
CALIBRATION FUNCTION PULSE REPETITION
CALIBRATED TOLERANCE IN PERCENT -4.0 TO 4.0
OUTPUT WAVE SHAPE COSINE AND SQUARE
OPERATING CONTROL METHOD MANUAL
CONTROL TYPE LOCAL
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS NOT RATED
AVERAGE LIFE MEASUREMENT NOT RATED
MAXIMUM OPERATING ALTITUDE RATING NOT RATED
OPERATING TEMP RANGE NOT RATED
VIBRATION RESISTANCE RANGE IN HERTZ NOT RATED
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS NOT RATED
EXTERNAL AC OPERATING VOLTAGE IN VOLTS 115.0 NOMINAL SINGLE VOLTAGE
OPERATING AC FREQUENCY IN HERTZ 50.0 MINIMUM SINGLE VOLTAGE 420.0 MAXIMUM SINGLE VOLTAGE
PHASE SINGLE
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN PORTABLE
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 20.375 INCHES NOMINAL
OVERALL HEIGHT 18.438 INCHES NOMINAL
OVERALL WIDTH 20.375 INCHES NOMINAL
IDENTIFICATION DESIGNATOR ANUPM55B80058
MANUFACTURERS CODE 02048
DESIGN CONTROL REFERENCE 96-001

Restrictions/Controls & Freight Information | NSN 6625-00-905-9096

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating W Rating Variable
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-00-905-9096

Category Code Description
Cognizance Codes7ZGeneral purpose electronic test equipment to support various Naval Systems Commands equipment/programs.
Naval Inventory Control Point, Mechanicsburg
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityHDepot Level Reparable
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative