Product Details | VOLTMETER

6625-01-013-7229 An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

Part Alternates: 702551010000, 7025-5101-0000, 6625-01-013-7229, 01-013-7229, 6625010137229, 010137229

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 07 DEC 1975 01-013-7229

Drawings & Photos | NSN 6625-01-013-7229


Cross Reference | NSN 6625-01-013-7229

Part Number Cage Code Manufacturer
7025-5101-0000 80145 LFE INSTRUMENTS A MARK IV CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-013-7229

Technical Data | NSN 6625-01-013-7229

Characteristic Specifications
INSTALLATION DESIGN PANEL
(NON-CORE DATA) PANEL FOR WHICH DESIGNED MAGNETIC
(NON-CORE DATA) CIRCUIT CONSTRUCTION TYPE NONELECTRONIC
INDICATOR TYPE DIAL W/POINTER
MEASUREMENT RANGE 0.0 TO 30.0 VOLTS, DC SINGLE INDICATOR SINGLE RANGE
ACCURACY IN PERCENT -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
SCALE GRADUATION TYPE LINEAR SINGLE INDICATOR SINGLE RANGE
SCALE DIVISION QUANTITY 30 SINGLE INDICATOR SINGLE RANGE
POINTER COLOR BLACK SINGLE INDICATOR SINGLE RANGE
DIAL SCALE MARKING COLOR BLACK SINGLE INDICATOR SINGLE RANGE
BACKGROUND COLOR WHITE SINGLE INDICATOR SINGLE RANGE
MOVEMENT TYPE MOVING COIL, PERMANENT MAGNET
MOVEMENT SUSPENSION METHOD TAUT BAND
CIRCUIT ATTACHMENT METHOD AND QUANTITY 2 THREADED STUD
SCALE SELECTION METHOD TERMINAL
POWER SOURCE EXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED DC
STYLE DESIGNATOR C2 RECTANGULAR FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE 2.220 INCHES MAXIMUM
METER DEPTH BEHIND MOUNTING FLANGE 1.240 INCHES MAXIMUM
OVERALL HEIGHT 2.410 INCHES MAXIMUM
OVERALL LENGTH 2.475 INCHES NOMINAL
OVERALL WIDTH 2.810 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD
MOUNTING STUD DIAMETER 0.112 INCHES NOMINAL
MOUNTING STUD LENGTH 0.550 INCHES MINIMUM AND 0.570 INCHES MAXIMUM
MOUNTING ARRANGEMENT STYLE E1 TWO HOLE/STUD
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 2.688 INCHES NOMINAL
MATERIAL PLASTIC
NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED
FEATURES PROVIDED ZERO ADJUSTER
SPECIAL FEATURES RUGGEDIZED
III FSC APPLICATION DATA TEST SET,ELECT. EQUIP.

Restrictions/Controls & Freight Information | NSN 6625-01-013-7229

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 136740 METERS ELEC/PARTS
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 657 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable