NSN 6625-01-044-0254 PD88MMTRBCID76.1, PD88MMTRBCID761, 451 OPT P1 P2 P5
Product Details | DIGITAL READOUT ELECTRONIC COUNTER
6625-01-044-0254 An instrument used to count the frequency of recurrent electronic events and display the count on the panel of the instrument in numeric form. May also include facilities for a readout printed on tape. May include facilities for a very accurate output which can be used as a secondary transfer standard. It can be used to measure frequency, period, time interval, phase angle, frequency ratio, and for multiple period averaging. See also COUNTER, ELECTRONIC, DIGITAL and INDICATOR, DIGITAL DISPLAY.
Part Alternates: PD88MMTRBCID76.1, PD88MMTRBCID761, 451 OPT P1 P2 P5, 451OPTP1P2P5, 6625-01-044-0254, 01-044-0254, 6625010440254, 010440254
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 05 JUL 1977 | 01-044-0254 | 26835 ( COUNTER, ELECTRONIC, DIGITAL READOUT ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6625-01-044-0254
Technical Data | NSN 6625-01-044-0254
| Characteristic | Specifications |
|---|---|
| MEASUREMENT TYPE | FREQUENCY |
| FREQUENCY RANGE | 0.300 TO 18.000 GIGAHERTZ OVERALL |
| ACCURACY RATING | TIME BASE ACCURACY PORM 1 COUNT,TIME BASE ACCURACY PORM AVERAGING ERROR PORM GATE ERROR |
| DISPLAY TYPE | NUMERIC READOUT TUBE |
| DISPLAY DIGIT QUANTITY | 7 |
| DISPLAY UNITS INDICATOR | INCLUDED |
| DISPLAY POSITIONED DECIMAL POINT | NOT PROVIDED |
| SOLID STATE FEATURE | INCLUDED |
| ELECTRICAL CONNECTION QUANTITY | 2 |
| ELECTRICAL CONNECTION TYPE | BNC |
| CURRENT TYPE | AC |
| VOLTAGE RATING | 100.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM |
| FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| PHASE | SINGLE |
| WATTAGE RATING IN WATTS | 100.0 |
| OVERALL LENGTH | 19.000 INCHES NOMINAL |
| OVERALL WIDTH | 16.000 INCHES NOMINAL |
| OVERALL HEIGHT | 3.500 INCHES NOMINAL |
| MOUNTING METHOD | RACK |
| PLUG-IN UNITS PROVISION | NOT INCLUDED |
| STANDARD FREQUENCY OUTPUT FEATURE | INCLUDED |
| OUTPUT FREQUENCY RATING | 10.0 MEGAHERTZ NOMINAL |
| FREQUENCY ACCURACY/STABILITY | 3 PARTS PER 10,000,000 PER MONTH |
| ACCESSORY COMPONENT QUANTITY | 2 |
| ACCESSORY CONTROLLING AGENCY | DANA LABORATORIES INC |
| ACCESSORY COMPONENT NAME | POWER CORD,INSTRUCTION MANUAL |
| III SPECIFIC USAGE DESIGN | ELECTRONIC TEST EQUIPMENT |
| MANUFACTURERS CODE | 34257 |
| DESIGN CONTROL REFERENCE | 451 OPT P1 P2 P5 |
Restrictions/Controls & Freight Information | NSN 6625-01-044-0254
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | C | Munitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories. |
| Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
| Less than car load rating | M | 85 |
| Less than truck load rating | J | 100.2 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | V | Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 6625-01-044-0254
| Category | Code | Description |
|---|---|---|
| Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
| Price Validation | X | The current standard price has been validated and the previous price was erroneous.
|
| Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
| Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
| Agency | DF | Department of the Air Force |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | S | AF Equipment Management System (AFEMS) |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |