NSN 6625-01-065-3432 545AS1484A, 545A-S1484A, 01-065-3432
Product Details | SYNCHRO TEST SET
6625-01-065-3432 A test set primarily designed for use in making examinations of the operation of synchros, such as measuring the accuracy of angular motion. See also TRANSFORMER, SYNCHRO OVERLOAD.20449200058Aircraft Maintenance and Repair Shop Specialized Equipment49310062Fire Control Maintenance and Repair Shop Specialized Equipment49350070Guided Missile Maintenance, Repair, and Checkout Specialized Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: 545AS1484A, 545A-S1484A, 6625-01-065-3432, 01-065-3432, 6625010653432, 010653432
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 15 SEP 1978 | 01-065-3432 | 03678 ( TEST SET, SYNCHRO ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-065-3432
Related Products | NSN 6625-01-065-3432
Technical Data | NSN 6625-01-065-3432
| Characteristic | Specifications |
|---|---|
| TEST TYPE FOR WHICH DESIGNED | SYNCHRO/RESOLVER ANGLE MEASUREMENTS |
| OPERATING TEST CAPABILITY | 2 INPUT CHANNELS; SIGNAL INPUTS 11.8V, 26.0V, 90V LINE-LINE; CHANNEL 1 SYNCHRO; CHANNEL 2 RESOLVER; ANGULAR RANGE 0 TO 359.99 DEGREES; DISPLAY 6 DIGITS |
| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| AC VOLTAGE RATING | 115.0 VOLTS NOMINAL AND 250.0 VOLTS NOMINAL |
| FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM |
| PHASE | SINGLE |
| INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
| DEPTH | 19.000 INCHES NOMINAL |
| HEIGHT | 5.219 INCHES NOMINAL |
| WIDTH | 19.000 INCHES NOMINAL |
| SPECIAL FEATURES | RACK MOUNTED |
| III SUPPLEMENTARY FEATURES | MANUFACTURERS NAME: INDICATOR,ANGLE POSITION |
Restrictions/Controls & Freight Information | NSN 6625-01-065-3432
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
| Less than car load rating | P | 77.5 |
| Less than truck load rating | J | 100.2 |
| Water commodity Code | 738 | unknown |
| Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-01-065-3432
| Category | Code | Description |
|---|---|---|
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
| Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
| Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
| Agency | DF | Department of the Air Force |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | S | AF Equipment Management System (AFEMS) |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |