NSN 6625-01-081-2711 8654AOPTION003, 01-081-2711, 010812711
Product Details | SIGNAL GENERATOR
6625-01-081-2711 An instrument which produces a continuous audio and/or radio frequency voltage, and which is designed for test purposes only. It may provide an output at one or more fixed frequencies or be continuously variable over one or more bands. The fixed frequency type is distinguished from CALIBRATOR, FREQUENCY in that it is a voltage source and is not primarily intended for checking frequencies from other sources. Excludes GENERATOR, INTERFERENCE.
Part Alternates: 8654AOPTION003, 6625-01-081-2711, 01-081-2711, 6625010812711, 010812711
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 10 AUG 1979 | 01-081-2711 | 03901 ( GENERATOR, SIGNAL ) |
Cross Reference | NSN 6625-01-081-2711
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 8654AOPTION003 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-081-2711
Related Products | NSN 6625-01-081-2711
Technical Data | NSN 6625-01-081-2711
| Characteristic | Specifications |
|---|---|
| FREQUENCY RANGE RATING | 10.000 TO 510.000 MEGAHERTZ |
| FREQUENCY BAND QUANTITY | 6 |
| CALIBRATION ACCURACY RATING | PORM 3.000 PCT AFTER 2 HOURS WARM UP |
| OUTPUT IMPEDANCE RATING | 50.0 OHMS NOMINAL |
| MODULATOR LOCATION | INTERNAL |
| MODULATION TYPE | AM AND FM |
| CURRENT TYPE | AC |
| VOLTAGE RATING | 100.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM |
| FREQUENCY RATING | 48.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM |
| OVERALL LENGTH | 317.5 MILLIMETERS NOMINAL |
| OVERALL WIDTH | 266.0 MILLIMETERS NOMINAL |
| OVERALL HEIGHT | 101.6 MILLIMETERS NOMINAL |
| MOUNTING TYPE | PORTABLE |
| MANUFACTURERS CODE | 28480 |
| DESIGN CONTROL REFERENCE | 8654AOPTION003 |
Restrictions/Controls & Freight Information | NSN 6625-01-081-2711
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||