Product Details | SPECTRUM ANALYZER

6625-01-115-2877 An instrument specifically designed to measure the amplitude and frequency of the constituents of a complex electrical wave form. May include transducer mechanism for converting sound pressure into electrical energy.

Part Alternates: 306TDL, 6625-01-115-2877, 01-115-2877, 6625011152877, 011152877

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JUL 1981 01-115-2877

Cross Reference | NSN 6625-01-115-2877

Part Number Cage Code Manufacturer
306TDL 13048 SCIENTIFIC-ATLANTA INC SIGNAL PROCESSING SYSTEMS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-115-2877

Technical Data | NSN 6625-01-115-2877

Characteristic Specifications
UNIT TYPE STANDARD
FREQUENCY RANGE RATING 0.010 TO 50.000 KILOHERTZ
INDIVIDUAL PLUG-IN UNIT FREQUENCY NOT RATED
FREQUENCY BAND QUANTITY 5
FREQUENCY CHANNEL QUANTITY 1
FREQUENCY CALIBRATION ACCURACY RANGE IN PERCENT -0.01 TO 0.01
METER SCALE RANGE 30UV TO 100V
INPUT IMPEDANCE RATING 1.0 MEGOHMS NOMINAL
AC VOLTAGE RATING 115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 1000.0 HERTZ MAXIMUM
PHASE SINGLE
OVERALL WIDTH 16.500 INCHES NOMINAL
OVERALL HEIGHT 8.000 INCHES NOMINAL
OVERALL DEPTH 12.000 INCHES NOMINAL
MOUNTING METHOD BENCH AND RACK
RECORDING DEVICE ACCOMMODATION NOT PROVIDED
III UNPACKAGED UNIT WEIGHT 20.000 POUNDS
MANUFACTURERS CODE 13048
DESIGN CONTROL REFERENCE 306TDL

Restrictions/Controls & Freight Information | NSN 6625-01-115-2877

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating J 100.2
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable