Product Details | WAVEMETER

6625-01-147-3101 An item for the determination of the electrical wavelength or frequency being generated by an electronic equipment such as a radio transmitter. It may be placed in the radiation field of the equipment, thereby operating on the "absorption" principle, or connected into a transmission line or waveguide run between the equipment and a component such as an antenna, thereby operating on the tuned cavity resonance principle. It includes inscriptions from which the wavelength or frequency can be determined directly, or by reference to an associated calibration curve or tabulation. the wavemeter operates in accordance with its design function only when the equipment under measurement is operating. For items, such as grid dip meters, that determine the same information when the equipment under measurement is not operating, see FREQUENCY METER.

Part Alternates: WA-10, WA1000, WA-1000, WA10, 6625-01-147-3101, 01-147-3101, 6625011473101, 011473101

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 15 FEB 1983 01-147-3101

Cross Reference | NSN 6625-01-147-3101

Part Number Cage Code Manufacturer
WA-10 53422 EXFO BURLEIGH PRODUCTS GROUP INC.
WA-1000 53422 EXFO BURLEIGH PRODUCTS GROUP INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-147-3101

Technical Data | NSN 6625-01-147-3101

Characteristic Specifications
INSTRUMENT CALIBRATION RANGE 0.4 TO 1.0 MICROMETERS
PLUG-IN UNIT QUANTITY 0
INDICATOR TYPE DIGITAL COUNTER
CURRENT TYPE AC
VOLTAGE RATING 115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL
OPERATING FREQUENCY 50.0 HERTZ NOMINAL AND 60.0 HERTZ NOMINAL
PHASE TWO
INTERNAL BATTERY ACCOMMODATION NOT INCLUDED
OVERALL WIDTH 17.000 INCHES NOMINAL
OVERALL HEIGHT 6.900 INCHES NOMINAL
OVERALL DEPTH 12.000 INCHES NOMINAL
III UNPACKAGED UNIT WEIGHT 15.000 KILOGRAMS
MANUFACTURERS CODE 53422
DESIGN CONTROL REFERENCE WA-10

Restrictions/Controls & Freight Information | NSN 6625-01-147-3101

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating D 200
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-01-147-3101

Category Code Description
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each