Product Details | MULTIMETER

6625-01-162-6191 An instrument which is arranged to measure two or more different electrical quantities (such as volts, amps, and ohms) by means of associated circuits and switches. The value is usually expressed on a single calibrated dial or digital readout display. For items which are connected into a circuit and used chiefly to visually monitor an operation, see METER, MULTIPLE SCALE. See also COUNTER, ELECTRONIC, DIGITAL READOUT. Excludes BRIDGE (as modified).

Part Alternates: 8860AOPT05, 8860A-OPT05, 6625-01-162-6191, 01-162-6191, 6625011626191, 011626191

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 21 SEP 1983 01-162-6191

Drawings & Photos | NSN 6625-01-162-6191


Cross Reference | NSN 6625-01-162-6191

Part Number Cage Code Manufacturer
8860A-OPT05 89536 FLUKE CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-162-6191

Technical Data | NSN 6625-01-162-6191

Characteristic Specifications
INSTALLATION DESIGN BENCH
(NON-CORE DATA) CIRCUIT CONSTRUCTION TYPE ELECTRONIC, SOLID STATE
INDICATOR TYPE DIGITAL DISPLAY
DISPLAY TYPE LIGHT EMITTING DIODE
DISPLAY DIGIT QUANTITY 5-1/2
MEASUREMENT RANGE 0.0 TO 200.0 MILLIVOLTS SINGLE INDICATOR 1ST RANGE 0.0 TO 2.0 VOLTS SINGLE INDICATOR 2ND RANGE 0.0 TO 20.0 VOLTS SINGLE INDICATOR 3RD RANGE 0.0 TO 200.0 VOLTS SINGLE INDICATOR 4TH RANGE 0.0 TO 1000.0 VOLTS SINGLE INDICATOR 5TH RANGE
ACCURACY RATING PORM0.004 PCT OF READING PLUS 3 DIGITS SINGLE INDICATOR 1ST RANGE PORM0.004 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 2ND RANGE PORM0.004 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 3RD RANGE PORM 0.004 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 4TH RANGE PORM 0.004 PCT OF READING PLUS 2 DIGITS SINGLE INDICATOR 5TH RANGE
SCALE SELECTION METHOD SWITCH
POWER SOURCE EXTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED AC
OPERATING VOLTAGE RATING IN VOLTS 100.0 AC MINIMUM AND 240.0 AC MAXIMUM
FREQUENCY RATING 40.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM
INTERFACE COMPATIBILITY IEEE-488
STYLE DESIGNATOR D8 PORTABLE W/TILT VIEW HANDLE
OVERALL DEPTH 14.600 INCHES NOMINAL
OVERALL HEIGHT 3.500 INCHES NOMINAL
OVERALL WIDTH 8.500 INCHES NOMINAL
NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED
FURNISHED ITEMS AND QUANTITY LINE CORD 1; TEST LEADS; INSTRUCTION/SERVICE MANUAL 1; IEEE-488 QUICK REFERENCE GUIDE 1; INSTRUMENT PERFORMANCE RECORD
SPECIAL FEATURES TEMPERATURE RANGE 0 DEG C TO 50 DEG C OPERATING,MINUS 40 DEG C TO PLUS 70 DEG C STORAGE; HUMIDITY RANGE 80 PCT RH 0 TO 35 DEG C,70 PCT TO 50 DEG C; WARMUP TIME 1 HOUR TO RATED SPECS
MANUFACTURERS CODE 89536
DESIGN CONTROL REFERENCE 8860A-OPT05

Restrictions/Controls & Freight Information | NSN 6625-01-162-6191

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating D 200
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-01-162-6191

Category Code Description
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1