Product Details | FLUXMETER

6625-01-195-1068 An electrical instrument which measures magnetic flux. With appropriate calibration it can be used for measurement of the intensity of a magnetic field. See also METER, FIELD STRENGTH.

Part Alternates: DM2220, DM-2220, 6625-01-195-1068, 01-195-1068, 6625011951068, 011951068

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 22 NOV 1984 01-195-1068

Demand History | NSN 6625-01-195-1068

Part Number Request Date QTY Origin
6625-01-195-1068 2025-06-156 1 US

Cross Reference | NSN 6625-01-195-1068

Part Number Cage Code Manufacturer
DM-2220 02169 SCHONSTEDT INSTRUMENT CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-195-1068

Technical Data | NSN 6625-01-195-1068

Characteristic Specifications
FLUX DENSITY 20000.0 GAUSS MINIMUM AND 200000.0 GAUSS MAXIMUM
SCALE DIRECTION AND RANGE 0 TO 1999 CLOCKWISE
SCALE LINEARITY LINEAR
SCALE DIVISION QUANTITY 1999
PROBE HANDLE INCLUDED
CURRENT TYPE AC
VOLTAGE RATING 115.0 VOLTS NOMINAL
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
PHASE SINGLE
CASE MATERIAL ANY ACCEPTABLE
OVERALL LENGTH 8.250 INCHES NOMINAL
OVERALL DEPTH 4.750 INCHES NOMINAL
OVERALL HEIGHT 11.000 INCHES NOMINAL
SPECIAL FEATURES PROBE CABLE LENGTH 8 FEET; DIGITAL DISPLAY; ACCURACY PORM 0.5 PCT OF FULL SCALE PORM 1 COUNT
MANUFACTURERS CODE 02169
DESIGN CONTROL REFERENCE DM-2220

Restrictions/Controls & Freight Information | NSN 6625-01-195-1068

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information