NSN 6625-01-198-5942 DMS28516, DMS285-16, 27708
Product Details | RADIO FREQUENCY POWER DIVIDER
6625-01-198-5942 An item specifically designed to separate incoming radio frequency power into predetermined proportional values at its output terminals.20358950037Miscellaneous Communication Equipment59850043Antennas, Waveguides, and Related Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: DMS28516, DMS285-16, 27708, 6625-01-198-5942, 01-198-5942, 6625011985942, 011985942
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 10 JAN 1985 | 01-198-5942 | 60411 ( DIVIDER, POWER, RADIO FREQUENCY ) |
Demand History | NSN 6625-01-198-5942
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 27708 | 2013-06-164 | 1 | CL |
| 6625-01-198-5942 | 2012-07-206 | 6 | US |
| 6625-01-198-5942 | 2008-11-318 | 5 | United States |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-198-5942
Related Products | NSN 6625-01-198-5942
Technical Data | NSN 6625-01-198-5942
| Characteristic | Specifications |
|---|---|
| SPECIAL FEATURES | RATED1 TO 16 GHZ; 0.02 TO 0.03 DB VSWR IN 1.3 TO 1.7; VSWR OUT 1.3 TO 1.6; ISOLATION 10 DB TO 20 DB; INSERTION LOSS 0.5 DB TO O.8 DB; SMA FEMALE CONNECTORS 2; 1.750 IN BY 0.437 IN BY 0.437 IN |
Restrictions/Controls & Freight Information | NSN 6625-01-198-5942
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||