NSN 6625-01-275-6268 5350B001, 5350B-001, 01-275-6268
Product Details | DIGITAL READOUT ELECTRONIC COUNTER
6625-01-275-6268 An instrument used to count the frequency of recurrent electronic events and display the count on the panel of the instrument in numeric form. May also include facilities for a readout printed on tape. May include facilities for a very accurate output which can be used as a secondary transfer standard. It can be used to measure frequency, period, time interval, phase angle, frequency ratio, and for multiple period averaging. See also COUNTER, ELECTRONIC, DIGITAL and INDICATOR, DIGITAL DISPLAY.
Part Alternates: 5350B001, 5350B-001, 6625-01-275-6268, 01-275-6268, 6625012756268, 012756268
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 23 MAR 1988 | 01-275-6268 | 26835 ( COUNTER, ELECTRONIC, DIGITAL READOUT ) |
Demand History | NSN 6625-01-275-6268
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 6625-01-275-6268 | 2024-02-46 | 2 | AU |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-275-6268
Related Products | NSN 6625-01-275-6268
Technical Data | NSN 6625-01-275-6268
| Characteristic | Specifications |
|---|---|
| MEASUREMENT TYPE | FREQUENCY |
| FREQUENCY RANGE | 0.000 TO 10.000 GIGAHERTZ OVERALL |
| ACCURACY RATING | PROM 1 LSD PORM TIME-BASE ERROR X FREQUENCY |
| DISPLAY TYPE | NEON COLUMNAR |
| DISPLAY DIGIT QUANTITY | 11 |
| CURRENT TYPE | AC |
| VOLTAGE RATING | 90.0 VOLTS MINIMUM AND 252.0 VOLTS MAXIMUM |
| INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
| OVERALL LENGTH | 16.000 INCHES NOMINAL |
| OVERALL WIDTH | 14.000 INCHES NOMINAL |
| OVERALL HEIGHT | 5.250 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 6625-01-275-6268
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||
Management | NSN 6625-01-275-6268
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 3 | Marine Corps Appropriation Stores Account Principal Item. |
| Combat Essentiality Code | 1 | Combat Essential End Item. End item equipments whose availability in a combat ready condition is essential for execution of the combat and training missions of the command. |
| Materiel Management Code | 4 | Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665 |
| Echelon Management Code | 3 | Headquarters Marine Corps All Marine Corps-managed items managed by the ICP on a |
| Echelon Identification Code | A | Type 1 End Items 1 |
| Operational Test Code | 3 | All items requiring calibration. Items may be technical or non-technical in nature, (i.e., electronic test equipment, meters, gauges, torque wrenches, etc.) All OTC 3 items require established calibration procedures.BLANK |
| Source of Supply | MPB | Commanding General Marine Corps Logistics Command 566-2, Bldg. 3700 Albany, GA 31704-5000 |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Acquisition Advice Codes | H | DIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 7Z | General purpose electronic test equipment to support various Naval Systems Commands equipment/programs. Naval Inventory Control Point, Mechanicsburg |
| Special Material ID | TE | General purpose electronic test equipment |
| Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
| Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
| Agency | DN | Department of the Navy |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | H | Depot Level Reparable |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |