Product Details | SPECIAL SCALE METER

6625-01-279-3763 An electrically operated instrument which has a custom scale or digital readout display, but the unit of measurement given is not covered by a more specific item name. For items without a specified unit of measurement, see METER, ARBITRARY SCALE.

Part Alternates: 6960001, 6960-001, 6625-01-279-3763, 01-279-3763, 6625012793763, 012793763

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 17 MAY 1988 01-279-3763

Cross Reference | NSN 6625-01-279-3763

Part Number Cage Code Manufacturer
6960-001 09553 MARCONI ELECTRONICS INC MARCONI INSTRUMENTS DIV
6960-001 51190 AEROFLEX WICHITA, INC. DBA IFR SYSTEMS
6960-001 U6924 ASTRIUM LTD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-279-3763

Technical Data | NSN 6625-01-279-3763

Characteristic Specifications
INSTALLATION DESIGN BENCH OR RACK
INDICATOR TYPE DIGITAL DISPLAY AND VIBRATING REED
CIRCUIT CURRENT FOR WHICH DESIGNED AC
OPERATING VOLTAGE RATING IN VOLTS 220.0 AC NOMINAL
FREQUENCY RATING 48.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM
PHASE SINGLE
INTERFACE COMPATIBILITY IEEE-488
MANUFACTURERS CODE 51190
DESIGN CONTROL REFERENCE 6960-001

Restrictions/Controls & Freight Information | NSN 6625-01-279-3763

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating A 400.0
Water commodity Code 576 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code Z Shipment is not a consolidation, but does exceed 72 inches in one or more dimensions.
Air Commodity V Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-01-279-3763

Category Code Description
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each