NSN 6625-01-323-1521 TV220 , 1503C, 1503CA1
Product Details | METALLIC TIME DOMAIN REFLECTOMETER
6625-01-323-1521 A cable tester that uses time domain reflectometry to identify and locate cable faults.
Part Alternates: TV220 , 1503C, 1503CA1, 1503C-A1, 4042478, 404-2478 , 6625-01-323-1521, 01-323-1521, 6625013231521, 013231521
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 22 JUL 1990 | 01-323-1521 | 66586 ( REFLECTOMETER, METALLIC TIME DOMAIN ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-323-1521
Related Products | NSN 6625-01-323-1521
Technical Data | NSN 6625-01-323-1521
| Characteristic | Specifications |
|---|---|
| POWER SOURCE | EXTERNAL AND SELF-CONTAINED |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 12.0 DC AND 115.0 AC |
| FREQUENCY IN HERTZ | 60.0 |
| MAXIMUM MEASURED DISTANCE | 50000.0 FEET |
| OVERALL LENGTH | 19.000 INCHES NOMINAL |
| OVERALL HEIGHT | 6.500 INCHES NOMINAL |
| SPECIAL FEATURES | ITEM WEIGHS 23 LBS: INCLUDES: OPERATOR'S MANUAL (070-7323-02), 50 OHM BNC TERMINATOR (011-0123-00), PRECISION 93 OHM CABLE (012-1351-00), BNC FEMALE-TO-FEMALE ADAPTER (103-0028-00), BNC FEMALE-TO-CLIP LEADS ADAPTER (013-0261-00), ACCESSORY POUCH (016-0814-00), OPTION PORT COVER (200-3737-00), CALCULATOR SLIDE RULE (033-1419-00), AC POWER CORD, SPARE FUSE, INTERNAL BATTERY (040-1276-01); MAXIMUM AC IS 230V; MAXIMUM HZ 440; SINGLE ITEM W/HOUSING; SINGLE PHASE |
| III PART NAME ASSIGNED BY CONTROLLING AGENCY | METALLIC CABLE TESTER (MTDR) |
Restrictions/Controls & Freight Information | NSN 6625-01-323-1521
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
| Less than car load rating | P | 77.5 |
| Less than truck load rating | J | 100.2 |
| Water commodity Code | 738 | unknown |
| Originating Activity Code | ZC | Canada ZD ZE |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Q | Extremely fragile items including delicate instruments. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 6625-01-323-1521
| Category | Code | Description |
|---|---|---|
| Fund Code | LP | Items initially authorized for local purchase. |
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
| Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
| Agency | DF | Department of the Air Force |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | U | AF Equipment Management System (AFEMS) |
| Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |