NSN 6625-01-336-8580 8111AOPTION001910, 01-336-8580, 013368580
Product Details | PULSE GENERATOR
6625-01-336-8580 An electronic device which develops a discontinuous electrical potential with an abrupt rate of change of voltage which determines the harmonic content of the pulse train. The duration of a single pulse output is relatively short compared to the time of the recurrence cycle. See also GENERATOR, SINGLE PULSE; and GENERATOR, ELECTRONIC MARKER.20358950037Miscellaneous Communication Equipment61150041Generators and Generator Sets, Electrical66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: 8111AOPTION001910, 6625-01-336-8580, 01-336-8580, 6625013368580, 013368580
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 03 APR 1991 | 01-336-8580 | 00411 ( GENERATOR, PULSE ) |
Demand History | NSN 6625-01-336-8580
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 910 | 2012-04-121 | 10 | IN |
Cross Reference | NSN 6625-01-336-8580
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 8111A OPTION 001,910 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-336-8580
Related Products | NSN 6625-01-336-8580
Technical Data | NSN 6625-01-336-8580
| Characteristic | Specifications |
|---|---|
| IMPEDANCE RATING PER CHANNEL | 50.000 OHMS OUTPUT CHANNEL |
| CALIBRATION FUNCTION | IMPEDANCE AND PULSE REPETITION |
| OUTPUT WAVE SHAPE | ISOSCELES TRIANGULAR AND SINE AND SQUARE |
| MAXIMUM CONTINUOUS OPERATING TIME IN HOURS | NOT RATED |
| AVERAGE LIFE MEASUREMENT | NOT RATED |
| MAXIMUM OPERATING ALTITUDE RATING | NOT RATED |
Restrictions/Controls & Freight Information | NSN 6625-01-336-8580
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||