NSN 6625-01-347-2983 HP8990A, 40081433 , 4029842
Product Details | PEAK POWER ANALYZER
6625-01-347-2983
Part Alternates: HP8990A, 40081433 , 4029842, 402-9842 , 8990A, 6625-01-347-2983, 01-347-2983, 6625013472983, 013472983
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 19 OCT 1991 | 01-347-2983 | 77777 ( ) |
Demand History | NSN 6625-01-347-2983
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| HP8990A | 2009-06-170 | 1 | Denmark |
| 6625-01-347-2983 | 2008-11-309 | 1 | US |
| HP8990A | 2008-08-232 | 1 | US |
Cross Reference | NSN 6625-01-347-2983
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 8990A | 1LQK8 | KEYSIGHT TECHNOLOGIES, INC. |
| 8990A | 1MY97 | AGILENT TECHNOLOGIES, INC. DIV AGILENT TECHNOLOGIES |
| 8990A | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
| HP8990A | 1MY97 | AGILENT TECHNOLOGIES, INC. DIV AGILENT TECHNOLOGIES |
| HP8990A | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-347-2983
Related Products | NSN 6625-01-347-2983
Technical Data | NSN 6625-01-347-2983
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 16.620 INCHES NOMINAL |
| OVERALL WIDTH | 14.400 INCHES NOMINAL |
| OVERALL HEIGHT | 7.650 INCHES NOMINAL |
| CURRENT RATING | 250.000 AMPERES |
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | ANALYZER,PEAK POWER PERFORMS (8) EIGHT AUTOMATIC TIMING MEASUREMENTS (RISE TIME,FALL TIME, PULSE WIDTH,PRI,PRF, DUTY CYCLE, AND DELAY). FIVE (5)PRF, DUTY CYCLE, AND DELAY). FIVE (5)POWER MEASUREMENTS(PEAK POWER, AVERAGEPOWER, PULSE TOP/BASE AMPLITUDE, AND OVERSHOOT). SENSOR INPUTS (CHANNELS 1& 4) FREQUENCT RANGE: 50MHZ TO 40 GHZ,SENSOR DEPENDANT. POWER RANGE: -32 TO +20DBM. VIDEO INPUTS - CHANNELS 2&3 |
| SPECIAL FEATURES | CSBH-VOLTAGE IN VOLTS AND CURRENTTYPE-GENERAL CHARACTERISTICS: POWER REQUIREMENTS: VOLTAGE:90-132 OR 198- 264 VAC; 48-66 HZ. POWER: 250 VA MAX |
| MANUFACTURERS CODE | 1LQK8 |
| DESIGN CONTROL REFERENCE | 8990A |
Restrictions/Controls & Freight Information | NSN 6625-01-347-2983
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
| Less than car load rating | P | 77.5 |
| Less than truck load rating | J | 100.2 |
| Water commodity Code | 738 | unknown |
| Originating Activity Code | ZT | Norway ZU ZW |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Q | Extremely fragile items including delicate instruments. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-01-347-2983
| Category | Code | Description |
|---|---|---|
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Fund Code | RO | Major repair. |
| Materiel Management Aggregation Code | SO | TG:SPECIAL OPERATIONAL FORCES (SOF) PECULIAR |
| Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
| Agency | DF | Department of the Air Force |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | T | AF Recoverable Assembly Management System (AFRAMS) |
| Acquisition Advice Codes | M | RESTRICTED REQUISITIONS-MAJOR OVERHAUL (Service/Agency use only.) # Items (Assemblies and/or component parts) which for lack of specialized tools, test equipment, etc., can be used only by major overhaul activities. Base, post, camp or station activities will not requisition unless authorized to perform major overhaul function. |
| Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |