Product Details | VOLTAGE CALIBRATOR

6625-01-356-6950 An item specifically designed to determine by comparison accurate input and output voltages of major electronic components. Excludes VOLTMETER and VOLTMETER, ELECTRONIC.

Part Alternates: STCC64D1004, STCC64D100-4, 5440B/MM, 5440BMM, 6625-01-356-6950, 01-356-6950, 6625013566950, 013566950

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 09 APR 1992 01-356-6950

Cross Reference | NSN 6625-01-356-6950

Part Number Cage Code Manufacturer
5440B/MM 89536 FLUKE CORPORATION
STCC64D100-4 04236 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN SPACE SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-356-6950

Technical Data | NSN 6625-01-356-6950

Characteristic Specifications
INSTRUMENT CALIBRATION RANGE 0.0 TO 1100VDC
CALIBRATION RANGE QUANTITY 4
CALIBRATION ACCURACY RATING PORM 1.5 PPM PLUS 5 MICROVOLTS AT11V TO PORM 2.5 PPM PLUS 400 MICROVOLTS AT 1100V
AC VOLTAGE RATING 100.0 VOLTS NOMINAL AND 240.0 VOLTS NOMINAL
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
PHASE SINGLE
OVERALL WIDTH 430.0 MILLIMETERS NOMINAL
OVERALL HEIGHT 240.0 MILLIMETERS NOMINAL
OVERALL DEPTH 610.0 MILLIMETERS NOMINAL
MOUNTING METHOD RACK
SPECIAL FEATURES IEEE488 & RS-232C & BOOST INTERFACES; REAR OUTPUTS; 4 OUTPUT RANGES,0 TO 11VDC,11 TO 22VDC,22 TO 275VDC,275 TO 1100VDC; OUTPUT CURRENT 0 T0 60 MILLIAMPS UP TO 22VDC,0 TO 25 MILLIAMPS UP TO 1100VDC; HAS PROGRAM MODULE FOR PRESETTING FOR TEST SEQUENCES; 40 CHARACTER ALPHA-NUMERIC VACUUM FLUORESCENT DISPLAY; POWER CONSUMPTION 84 WATTS IN STANDBY,145 WATTS NOMINAL
III END ITEM IDENTIFICATION LGM118A MISSLE
III UNPACKAGED UNIT WEIGHT 30.2 KILOGRAMS
III SUPPLEMENTARY FEATURES OPTION MM IS RACKMOUNTING KITS,R/N M08-205-600 AND M00-280-610
MANUFACTURERS CODE 89536
DESIGN CONTROL REFERENCE 5440B/MM

Restrictions/Controls & Freight Information | NSN 6625-01-356-6950

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information