NSN 6625-01-365-1949 FTS4060075116, FTS4060-075-116, FTS4060116
Product Details | FREQUENCY STANDARD
6625-01-365-1949 An item that can generate a fundamental frequency with a high degree of accuracy. Harmonics of this fundamental are then used as a reference point for checking throughout the radio spectrum. The standard may be stable crystal oscillator, noncrystal oscillator, tuning fork, atomic beam, molecular beam, gas cell, quantum mechanical resonator, or the like.
Part Alternates: FTS4060075116, FTS4060-075-116, FTS4060116, FTS4060-116, 13306551, 1330655-1, 6625-01-365-1949, 01-365-1949, 6625013651949, 013651949
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 02 OCT 1992 | 01-365-1949 | 42641 ( FREQUENCY STANDARD ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-365-1949
Related Products | NSN 6625-01-365-1949
Technical Data | NSN 6625-01-365-1949
| Characteristic | Specifications |
|---|---|
| UNIT TYPE | STANDARD |
| FREQUENCY RANGE RATING | 5.000 TO 10.000 MEGAHERTZ |
| INDIVIDUAL PLUG-IN UNIT FREQUENCY | NOT RATED |
| FREQUENCY CHANNEL QUANTITY | 2 |
| INDIVIDUAL CHANNEL FREQUENCY | 5.0 MEGAHERTZ NOMINAL AND 10.0 MEGAHERTZ NOMINAL |
| AC VOLTAGE RATING | 115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL |
| FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM |
| PHASE | SINGLE |
| DC VOLTAGE RATING | 22.0 VOLTS MINIMUM AND 30.0 VOLTS MAXIMUM |
| OVERALL LENGTH | 21.000 INCHES NOMINAL |
| OVERALL WIDTH | 19.000 INCHES NOMINAL |
| OVERALL HEIGHT | 5.200 INCHES NOMINAL |
| MOUNTING METHOD | RACK |
| RECORDING DEVICE ACCOMMODATION | NOT PROVIDED |
| SPECIAL FEATURES | ACCURACY +/- 7X10-12; SETTABILITY +/- 3X10-12; OPERATING TEMP RANGE 0 TO 50DEG. C;STABILITY +/-3X10-12 OVER THE LIFE OF THE TUBE; SPECTRAL PURITY >81DB FOR 10MHZ AND >87 FOR 5MHZ; AMPLITUDE 1VRMS INTO 50 OHM LOAD; MONITOR OUTPUT IS A TYPE D CONNECTOR; WARMUP TIME IS 20MIN FOR 10 MHZ AND 45 MIN FOR 5MHZ; FRONT PANEL CONNECTORS FOR 1PPS,SYNC INPUT,ZEEMAN INPUT,RF OUTPUTS;OPERATING HUMIDITY,95% UP TO 50C; OPTION -116 IS TIME OF DAY DISPLAY AND A 1PPS OUTPUT; OPT -075 IS FOR AN 8 YEAR WARRANTY ON CESIUM BEAM TUBE; INTERNAL MICROPROCESSOR PROVIDE FOR POWER UP AUTOMATIC LOCK ROUTINE; CONTROLLED BY FRONT PANEL SWITCHES AND REMOTE CONTROL THRU REAR PANEL CONNECTOR |
| III UNPACKAGED UNIT WEIGHT | 60.000 POUNDS |
| III SUPPLEMENTARY FEATURES | WITHOUT -075 INDICATES 3 YEAR WARRANTY ON CESIUM BEAM TUBE |
| MANUFACTURERS CODE | 56219 |
| DESIGN CONTROL REFERENCE | FTS4060-075-116 |
Restrictions/Controls & Freight Information | NSN 6625-01-365-1949
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | N | The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
| Less than car load rating | ||
| Less than truck load rating | J | 100.2 |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | TA | Sacramento Air Logistics Center McClellan AFB, CA 95652-5609 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-01-365-1949
| Category | Code | Description |
|---|---|---|
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
| Source of Supply | FGZ | Ogden Air Logistics Center Hill AFB, UT 84056-5609 |
| Agency | DF | Department of the Air Force |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | T | AF Recoverable Assembly Management System (AFRAMS) |
| Acquisition Advice Codes | C | SERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |