NSN 6625-01-375-4685 2637500G001, 01-375-4685, 013754685
Product Details | ELECTRICAL-ELECTRONIC EQUIPMENT TEST STATION
6625-01-375-4685 A group of items including a console and peripheral equipment specifically designed for use in testing electrical-electronic equipment. May include self-test capabilities. See TEST STATION, GUIDED MISSILE; FAULT LOCATOR (as modified)20249200058Aircraft Maintenance and Repair Shop Specialized Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: 2637500G001, 6625-01-375-4685, 01-375-4685, 6625013754685, 013754685
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 11 MAY 1993 | 01-375-4685 | 39182 ( TEST STATION, ELECTRICAL-ELECTRONIC EQUIPMENT ) |
Demand History | NSN 6625-01-375-4685
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 6625-01-375-4685 | 2025-11-314 | 1 | IN |
| 6625-01-375-4685 | 2025-11-308 | 1 | IN |
Cross Reference | NSN 6625-01-375-4685
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 2637500G001 | 28527 | EXELIS INC. DBA ELECTRONIC SYSTEMS, INTEGRATED |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-375-4685
Related Products | NSN 6625-01-375-4685
Technical Data | NSN 6625-01-375-4685
| Characteristic | Specifications |
|---|---|
| COMPONENT QUANTITY | 22 |
| COMPONENT DOCUMENT ORIGIN | GOVERNMENT |
| NONSUPPLY ITEMS AND QUANTITIES | MODULATION ANALYZER,HP8901B,1; FREQUENCY/TIME INT COUNTER,HP5371A,1; SPECTRUM ANALYZER,HP8566B,1; SPECTRUM ANALYZER DISPLAY,HP85662A,1; OSCOPE,HP54510A,1; DISTORTION ANALYZER,HP8903B,1; AGILE SIGNAL GENERATOR,HP8645A,1; SIGNAL GENERATOR,HP8656B,1;PROGRAMMABLE WAVEFORM SYNTHESIZER,WAVETEK 178,1; LOGIC ANALYSIS MAINFRAME,HP16500,1; 80 CHANNEL LOGIC ANALYZER,HP16510B,1; POWER SUPPLY MAINFRAME,HP66000,1; POWER SUPPLY MODULE,HP66103,1; TIME CODE GENERATOR,STCG300-604,1; IEEE-488 INTERFACE,OPT J; 1 MPPS,100KPPS,10 KPPS TTL OUTPUT CARD,OPT. F.1; 800 KPPS LS-TTL OUTPUT,OPT SPEC; OVENIZED OSCILLATOR,OPT C3; MAINFRAME,HP E1400B,1; MULTIMETER,HP E1411B,1; DIGITAL WORD GENERATOR,TALON BE-64,1; BUS CONTROL UNIT,SCI BCU-VME-M,1; MULTIPLEXER,HP E1460A,1; FORM-C SWITCH,HP E1463A,2; MULTIPLEXER,HP E1472A,1; MULTIPLEXER EXPANDER,HP1473A,2; PROG DIGITAL I/O MODULE,TEKVX4802,1 |
| END ITEM IDENTIFICATION | AN/ARC-164 & AN/ARC-190 COMMUNICATIONS SYSTEMS |
| III USAGE DESIGN | HF/UHF RADIO SOFTWARE UPGRADES INTHE EXPANDABLE COMMUNICATION INTEGRATED SUPPORT ENVIRONMENT,(ECOMISE SYS) |
| III FUNCTIONAL DESCRIPTION | CORE UNIT CONTAINS TEST INST/CONTROL PROCESSORS WHICH SUPPORT TESTING OF TARGETED COMMUNICATIONS SYSTEMS |
| MANUFACTURERS CODE | 28527 |
| DESIGN CONTROL REFERENCE | 2637500G001 |
Restrictions/Controls & Freight Information | NSN 6625-01-375-4685
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | N | The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). |
| Automatic Data Processing Equipment: | 9 | To be assigned to an item containing embedded ADPE that meets one or more of the definitions for codes 1 through 6. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
| Less than car load rating | P | 77.5 |
| Less than truck load rating | J | 100.2 |
| Water commodity Code | 738 | unknown |
| Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | C | Chemical corps items and all other chemicals not covered in other classifications. When chemical item (as indicated by the DOT Proper Shipping Name) is sensitive as defined in Appendix A Section I of DoD 4500.32-R, Volume 1, second position must be from table 85, part 1. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-01-375-4685
| Category | Code | Description |
|---|---|---|
| Fund Code | LP | Items initially authorized for local purchase. |
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
| Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
| Agency | DF | Department of the Air Force |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | U | AF Equipment Management System (AFEMS) |
| Acquisition Advice Codes | L | LOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |