Product Details | RADIO FREQUENCY BOLOMETER

6625-01-380-9280 An item consisting of a radiant-energy heat-transducing element such as a thermistor, whose resistance changes with the absorption of radio frequency energy, contained in a cavity or other housing. May include tuning adjustments, pick-up loops, flexible transmission line, battery case, and the like. Usually used with a summation bridge to measure radio frequency power. For items consisting of a bolometer housed in a probe, see PROBE, WAVEGUIDE.

Part Alternates: VX1811, VX1811A, 53A5811, 53A-5811, 6625-01-380-9280, 01-380-9280, 6625013809280, 013809280

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 30 SEP 1993 01-380-9280

Cross Reference | NSN 6625-01-380-9280

Part Number Cage Code Manufacturer
53A-5811 80009 TEKTRONIX, INC. DBA TEKTRONIX
VX1811 80009 TEKTRONIX, INC. DBA TEKTRONIX
VX1811A 80009 TEKTRONIX, INC. DBA TEKTRONIX

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-380-9280

Technical Data | NSN 6625-01-380-9280

Characteristic Specifications
FREQUENCY RANGE RATING 0.1 TO 18000.0 MEGAHERTZ
BATTERY CASE NOT PROVIDED
III END ITEM IDENTIFICATION 53A-581MICROWAVE METER
III SUPPLEMENTARY FEATURES 50 OHM, RANGE 50 NWATTS TO 10MW, SWR 1.28: 1OOKHZ TO 12.4 GHZ, 1.34: 12.4 TO 18GHZ
MANUFACTURERS CODE 80009
DESIGN CONTROL REFERENCE VX1811A

Restrictions/Controls & Freight Information | NSN 6625-01-380-9280

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information