NSN 6625-01-382-3739 J2201A, J2263A, 01-382-3739
Product Details | ELECTRICAL CABLE TEST SET
6625-01-382-3739 A test set primarily designed for use in making examinations of electrical cables. Can be used for locating shorts, crosses, and grounds in electrical cables. This would also permit locating high resistant faults. See also TEST SET (1), POWER-SPECIAL PURPOSE ELECTRICAL CABLE ASSEMBLY. Excludes REFLECTOMETER, METALLIC TIME DOMAIN.
Part Alternates: J2201A, J2263A, 6625-01-382-3739, 01-382-3739, 6625013823739, 013823739
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 12 FEB 1998 | 01-382-3739 | 03633 ( TEST SET, ELECTRICAL CABLE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-382-3739
Related Products | NSN 6625-01-382-3739
Technical Data | NSN 6625-01-382-3739
| Characteristic | Specifications |
|---|---|
| TEST TYPE FOR WHICH DESIGNED | LOCAL AREA NETWORK (LAN)CABLE FAULTS |
| OPERATING TEST CAPABILITY | TIME DOMAIN REFLECTOMETER (TDR) DETECTS, LOCATES DISCONTINUITIS IN TWISTED-PAIR AND COAXIAL CABLES: MEASURES ELECTRICAL NOISE AND DC RESISTANCE; SIGNAL ATTENUATION MEASUREMENTS FROM 1-20MHZ |
| INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
| LENGTH | 7.500 INCHES NOMINAL |
| WIDTH | 4.000 INCHES NOMINAL |
| SPECIAL FEATURES | HAND HELD, BATTERY POWERED MEDIA SCANNER FOR ISOLATING WIRING PROBLEMS ON LANS |
| III END ITEM IDENTIFICATION | VAX6610 |
| III FUNCTIONAL DESCRIPTION | A NEXT SCANNER FOR LAN MONITORING AND DIAGNOSTICS; MESURES PHYSICAL PARAMETERS IN EVERY PART OF THE LAN; HAS TDR TIME DOMAIN REFLECTOMETER TO DETECT AND LOCATE DISCONINUTITIES AND EXPRESS THE RESULTS IN ENGLISH; MEASURES NOISE AND RESISTANCE IN THE LINE AND PRINTS OR STORES THE RESULTS; MEASURES SIGNAL LOSS, 10 BASE-T HUB ACTIVATION AND REMOTE ALARM GENERATION; TESTS SPECIFIC NETWORK TYPES INCLUDING MESUREMENT OF NEAR END CROSS TALKHGTHJAA1.000 |
| MANUFACTURERS CODE | 1MY97 |
| DESIGN CONTROL REFERENCE | J2263A |
Restrictions/Controls & Freight Information | NSN 6625-01-382-3739
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||