NSN 6625-01-390-1129 8K42, 01-390-1129, 013901129
Product Details | SIGNAL DATA RECORDER
6625-01-390-1129 An item which makes a permanent representation of electronic signal data derived from target parameters, guidance and evaluation signals, and the like, These signals may be above or below 20,000 hertz. They may be in digital and/or analog form, the characteristics of which limits useful playback to a compatable reproducer. These items usually include multichannel signal input facilities for the simultaneous recording of several types of signals. Excludes RECORDER, SOUND.20258950037Miscellaneous Communication Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments
Part Alternates: 8K42, 6625-01-390-1129, 01-390-1129, 6625013901129, 013901129
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 12 MAY 1994 | 01-390-1129 | 21118 ( RECORDER, SIGNAL DATA ) |
Cross Reference | NSN 6625-01-390-1129
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 8K42 | 31991 | SOLTEC, INC. |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6625-01-390-1129
Technical Data | NSN 6625-01-390-1129
| Characteristic | Specifications |
|---|---|
| SPECIAL FEATURES | STRIP CHART RECORDER |
| III END ITEM IDENTIFICATION | AN/AQM-29 |
| MANUFACTURERS CODE | 31991 |
| DESIGN CONTROL REFERENCE | 8K42 |
Restrictions/Controls & Freight Information | NSN 6625-01-390-1129
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
| Less than car load rating | J | 100.2 |
| Less than truck load rating | J | 100.2 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | V | Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-01-390-1129
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 6R | Aeronautical ground support equipment (reparable or investment type material) Naval Inventory Control Point, Philadelphia |
| Issue Repair, or Requisition | BS | Submit/refer requisitions to NAVICP PHIL. |
| Special Material Content | 2 | Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item |
| Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
| Agency | DN | Department of the Navy |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | X | Special Program Reparables |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |