Product Details | FAULT LOCATING INDICATOR

6625-01-394-6356 An electrically activated item specifically designed to indicate the occurrence of a malfunction in a component of an electronic set, central or system. It may indicate the malfunction by a pop-out button (e.g. ground fault interrupt outlets) or color change by emitted light or displayed in a window. The indicator may utilize a "push to test" button. It does not make quantitative or qualitative tests such a provided by test sets.

Part Alternates: 34087786001, 34087786-001, 6625-01-394-6356, 01-394-6356, 6625013946356, 013946356

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 12 AUG 1994 01-394-6356

Cross Reference | NSN 6625-01-394-6356

Part Number Cage Code Manufacturer
34087786-001 07479 MINELCO INC SUB OF TALLEY INDUSTRIES INC
34087786-001 09128 HONEYWELL INTERNATIONAL INC. DBA HONEYWELL

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-394-6356

Technical Data | NSN 6625-01-394-6356

Characteristic Specifications
CASE MATERIAL ALUMINUM
ELECTRICAL CONNECTION QUANTITY 2
PRESENTATION TYPE WINDOW
MARKING COLOR SPECIFIC USE FAULT-NO FAULT
CURRENT TYPE DC
DC VOLTAGE RATING 19.2 VOLTS MINIMUM AND 28.8 VOLTS MAXIMUM
COIL DC RESISTANCE 10350.0 OHMS MINIMUM AND 12650.0 OHMS MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED CASE
LENGTH 0.922 INCHES NOMINAL
DIAMETER 0.593 INCHES NOMINAL
SPECIAL FEATURES SELECTED FROM CAGEC 81349 P/N M83287/04-19;SELECTED FOR INCREASED VIBRATION TO WITHSTAND 20G VIBRATION VERIFIED BY AN ELECTRICAL FALSE TRANSFER TEST WHEREBY THE INDICATOR UNDER TEST SHALL NOT INDICATE A FAULT WITH 17.5 VDC APPLIED;POSITIVE TERMINAL IS IDENTIFIED BY A RED DOT

Restrictions/Controls & Freight Information | NSN 6625-01-394-6356

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information