NSN 6625-01-397-6369 E1416A, 01-397-6369, 013976369
Product Details | ELECTRICAL-ELECTRONIC TEST EQUIPMENT PLUG-IN UNIT
6625-01-397-6369 An electronic subassembly designed to be plugged into one or more basic pieces of test equipment to extend the capabilities of the basic instrument. The basic instrument cannot function without one or more plug-in units (as required) in position.20649200058Aircraft Maintenance and Repair Shop Specialized Equipment49310062Fire Control Maintenance and Repair Shop Specialized Equipment49330057Weapons Maintenance and Repair Shop Specialized Equipment49350070Guided Missile Maintenance, Repair, and Checkout Specialized Equipment66250070Electrical and Electronic Properties Measuring and Testing Instruments66350042Physical Properties Testing and Inspection
Part Alternates: E1416A, 6625-01-397-6369, 01-397-6369, 6625013976369, 013976369
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 15 OCT 1994 | 01-397-6369 | 66495 ( PLUG-IN UNIT, ELECTRICAL-ELECTRONIC TEST EQUIPMENT ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6625-01-397-6369
Technical Data | NSN 6625-01-397-6369
| Characteristic | Specifications |
|---|---|
| UNIT TYPE | POWER METER |
| FURNISHED ITEMS | ONE 5 FT. SENSOR CABLE |
| ACCESSORY COMPONENT QUANTITY | 1 |
| ACCESSORY IDENTIFYING NUMBER | HP11730A PART NO. |
| SPECIAL FEATURES | FREQUENCY: 100 KHZ/50 GHZ, 75 GHZ/110 GHZ SENSOR DEPENDENT; POWER RANGE: M70 TO P44 DBM,(100 PW TO 25 W), SENSOR DEPENDENT; DYNAMIC RANGE: 50 DB IN 10 DB RANGES; RESULTS UNITS: W, DBM (ABSOLUTE), PCT., DB (RELATIVE); ACCURACY: INSTRUMENTATION: ABSOLUTE MODE: PORM 0.02 DB OR PORM 0.5 PCT., ADD SENSOR LINEARITY PERCENTAGE FOR RANGES 4 OR 5; ZERO SET: PORM 0.5 PCT. OF FULL SCALE ON MOST SENSITIVE RANGE, DIVIDE BY 10 FOR EACH HIGHER RANGE, PORM 1 COUNT; POWER REFERENCE: 1.00 MW (50 MHZ OSCILLATOR FACTORY SET TO PORM 0.7 TRACEABLE TO NIST |
| III END ITEM IDENTIFICATION | F-15E ELECTRONIC TEST STATION |
| III FUNCTIONAL DESCRIPTION | FREQUENCY:ENTRY OF TEST SIGNAL FREQ. FOR CAL FACTOR SELECTION; OFFSET:CAN BE OFFSET BY PORM 99.99DB; RESOLUTION: SELECTION OF 0.1,0.01,0.001 DB;AVERAGING:1 TO 1024 READINGS;SENSOR TABLES:ENTRY/STORAGE UP TO 10 SENSOR CAL FACTOR VS FREQ.; SAVE/RECALL:10 COMPLETESTATES |
| III RELATIONSHIP TO SIMILAR EQUIPMENT | FUNC. EQUIV. TO HP4378/HP70100A |
| MANUFACTURERS CODE | 1LQK8 |
| DESIGN CONTROL REFERENCE | E1416A |
Restrictions/Controls & Freight Information | NSN 6625-01-397-6369
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 060500 | ELECTRICAL EQUIPMENT GROUP |
| Less than car load rating | ||
| Less than truck load rating | Z | No Rating |
| Water commodity Code | 652 | unknown |
| Originating Activity Code | TK | HQ AFMC/GLSC 401 SCM/GUMB Wright-Patterson AFB, OH 45433-5000 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | 2 | Arms/Weapons (all types including Inert Component Parts). When a 2 is indicated in the first position, then the special handling code must be determined from table 85 , part 1. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6625-01-397-6369
| Category | Code | Description |
|---|---|---|
| Materiel Management Aggregation Code | KV | TG:AUTOMATIC TEST EQUIPMENT (ATE) |
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Fund Code | RO | Major repair. |
| Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
| Agency | DF | Department of the Air Force |
| Service Organization | F | U.S. Air Force |
| Reparability | T | AF Recoverable Assembly Management System (AFRAMS) |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 2 | Marine Corps Appropriation Stores Account Secondary Items. |
| Combat Essentiality Code | 2 | Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items. |
| Materiel Management Code | 4 | Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665 |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Operational Test Code | 3 | All items requiring calibration. Items may be technical or non-technical in nature, (i.e., electronic test equipment, meters, gauges, torque wrenches, etc.) All OTC 3 items require established calibration procedures.BLANK |
| Source of Supply | MPB | Commanding General Marine Corps Logistics Command 566-2, Bldg. 3700 Albany, GA 31704-5000 |
| Agency | DM | U.S. Marine Corps |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | D | Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level. |
| Acquisition Advice Codes | M | RESTRICTED REQUISITIONS-MAJOR OVERHAUL (Service/Agency use only.) # Items (Assemblies and/or component parts) which for lack of specialized tools, test equipment, etc., can be used only by major overhaul activities. Base, post, camp or station activities will not requisition unless authorized to perform major overhaul function. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |