NSN 6625-01-469-3144 FLUKE80I110SNIST, 044X300, 2.224
Product Details | TEST PROBE-LEAD ASSEMBLY
6625-01-469-3144 A definite length of wire or cable with a CLIP, ELECTRICAL; CONNECTOR, PLUG, ELECTRICAL; CONNECTOR, RECEPTACLE, ELECTRICAL; JACK, TELEPHONE; JACK, TIP; PLUG, TIP; or the like on one or both ends and PROBE, TEST on either end but not on both ends. Electronic components, such as capacitors, electron tube, resistors, semiconductor devices, and the like are mounted into and included with the item for attenuation or amplification purposes. May or may not include accessories such as CLIP, ELECTRICAL; PROBE, TEST; TEST PROBE ATTACHMENT. For items without electronic components see, LEAD, TEST. For items designed for direct attachment to a PROBE-LEAD ASSEMBLY, TEST see PROBE, TEST. For items designed for indirect attachment to a PROBE-LEAD ASSEMBLY, TEST see TEST PROBE ATTACHMENT.
Part Alternates: FLUKE80I110SNIST, 044X300, 2.224 , 2224, 374TE110, 68K0756 , 80I110S, 80I-110S, 6625-01-469-3144, 01-469-3144, 6625014693144, 014693144
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 10 NOV 1999 | 01-469-3144 | 39884 ( PROBE-LEAD ASSEMBLY, TEST ) |
Demand History | NSN 6625-01-469-3144
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 6625-01-469-3144 | 2020-12-356 | 7 | US |
| 6625-01-469-3144 | 2020-12-352 | 2 | United States |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6625-01-469-3144
Technical Data | NSN 6625-01-469-3144
| Characteristic | Specifications |
|---|---|
| VOLTAGE IN VOLTS AND CURRENT TYPE | 600.0 AC |
| CURRENT RATING | 100.000 AMPERES |
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | CLAMP ON AC/DC CURRENT PROBE; MEASURES 10 TO 50 MA; 0.460 IN DIA; SAFETY RATING: 600 VRMS OVERVOLTAGE INSTALLATION CAT 2/300 VRMS OVERVOLTAGE INSTALLATION CAT 3; CONSISTS OF PROBE CABLE ASSY, PROBE BODY, RETRACTABLE HOOK TIP, GROUND LEAD W/CLIP; INSULATED BNC CONNECTOR; 3 PCT OF READING ACCURACY; COMPATIBLE FLUKE POWER METERS MODEL 40/41, SCOPEMETER TEST TOOLS AND OSCILLOSCOPES |
Restrictions/Controls & Freight Information | NSN 6625-01-469-3144
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||
Management | NSN 6625-01-469-3144
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
| Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
| Materiel Management Code | 0 | GSA MaterielItems cataloged by the Marine Corps and managed by the General Services Administration. |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Source of Supply | G69 | Department of Transportation Federal Aviation Administration ATTN: COE AML-030 TSF BLDG 215 PO BOX 25082 Oklahoma City, OK 73125-0082 |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
| Acquisition Advice Codes | G | GENERAL SERVICES ADMINISTRATION (GSA)/CIVIL AGENCY INTEGRATED MATERIEL MANAGED, STOCKED AND ISSUED Identifies GSA/Civil Agency-managed items available from GSA/Civil Agency supply distribution facilities. Requisitions and fund citations will be submitted in accordance with GSA/Civil Agency/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |