NSN 6625-01-506-3626 AA59372, A-A-59372, AA59372A
Product Details | OSCILLOSCOPE CALIBRATOR
6625-01-506-3626 An item by means of which the indications of an OSCILLOSCOPE may be calibrated.
Part Alternates: AA59372, A-A-59372, AA59372A, A-A-59372A, PD03WR/LEEC110, PD03WRLEEC110, 6625-01-506-3626, 01-506-3626, 6625015063626, 015063626
Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 27 MAR 2003 | 01-506-3626 | 00391 ( CALIBRATOR, OSCILLOSCOPE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6625-01-506-3626
Related Products | NSN 6625-01-506-3626
Technical Data | NSN 6625-01-506-3626
| Characteristic | Specifications |
|---|---|
| CALIBRATION TYPE | VARIABLE OUTPUT |
| AC VOLTAGE RATING | 110.0 VOLTS NOMINAL |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| PHASE | SINGLE |
| SPECIAL FEATURES | MUST BE EQUAL TO THE FLUKE 9500B/1100 O-SCOPE CALIBRATOR W/ ONE 9530 150PS AND 500PS PULSE RISE TIME AND 3.2 GHZ CAPABLE ACTIVE HEAD. AC CHARACTERISTIC OF OPERATION SHALL INCLUDE LEVELED SINE TO A MAXIMUM OF 1.1 GHZ AND RISE TIME CAPABILITY TO LESS THAN 150PS. SHALL BE CAPABLE OF UPGRADE TO AT LEAST 6.4 GHZ |
| MANUFACTURERS CODE | 58536 |
| NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | A-A-59372 |
Restrictions/Controls & Freight Information | NSN 6625-01-506-3626
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
| Less than car load rating | P | 77.5 |
| Less than truck load rating | J | 100.2 |
| Water commodity Code | 738 | unknown |
| Originating Activity Code | TK | HQ AFMC/GLSC 401 SCM/GUMB Wright-Patterson AFB, OH 45433-5000 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Q | Extremely fragile items including delicate instruments. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 6625-01-506-3626
| Category | Code | Description |
|---|---|---|
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
| Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
| Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
| Agency | DF | Department of the Air Force |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | S | AF Equipment Management System (AFEMS) |
| Acquisition Advice Codes | W | RESTRICTED REQUISITIONING-SPECIAL INSTRUCTIONS APPLY (NON-STOCKED ITEMS) Indicates stock number has been assigned to a generic item for use in bid invitations, allowance lists, etc., against which no stocks are ever recorded. Requisitions will be submitted only in accordance with IMM/Service requisitioning procedures. (This code will be used, when applicable, in conjunction with Phrase Code S (Stock as NSN(s)). It is considered applicable for use when a procurement source(s) becomes available. The Phrase Code S and the applicable stock as? NSN(s) will then be applied for use in stock, store and issue actions.) |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |



