Product Details | DATA TRANSMISSION LINE TEST SET

6625-01-570-5560 An item designed for making examinations and/or analyzing data transmission lines for correctness of transmitted data structures. It may or may not include a printer, hard or floppy disk drive, connection facilities for these items or the like.

Part Alternates: FST2310, FST-2310, 6625-01-570-5560, 01-570-5560, 6625015705560, 015705560

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 06 JAN 2009 01-570-5560

Cross Reference | NSN 6625-01-570-5560

Part Number Cage Code Manufacturer
FST-2310 61141 ACTERNA LLC DBA JDSU

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-570-5560

Technical Data | NSN 6625-01-570-5560

Characteristic Specifications
ELECTRICAL POWER SOURCE RELATIONSHIP ALTERNATE OPERATING
FREQUENCY RATING 45.0 HERTZ MINIMUM AND 65.0 HERTZ MAXIMUM
DEPTH 190.0 MILLIMETERS NOMINAL
AC VOLTAGE RATING 90.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM
TEST TYPE FOR WHICH DESIGNED CARRIER TRANSMISSION LINES FROM DS0 TO OC-48 RATES
INTERNAL BATTERY ACCOMMODATION INCLUDED
PART NAME ASSIGNED BY CONTROLLING AGENCY FST-2310 TESTPAD
DC VOLTAGE RATING 10.8 VOLTS NOMINAL
HEIGHT 57.0 MILLIMETERS NOMINAL
SPECIAL FEATURES COMPREHENSIVE TESTING W/ MULTI RATES/SERVICES/MODES; GUI INTERFACE; RUGGEDIZED; PERFORMS END-TO-END BER TESTING; ANALYZE NETWORK PERFORMANCE; ENSURES QOS; VERIFIES PROPER PROVISIONING OF MULTI/DEMULTIPLEXERS; VERIFIES PROPER NETWORK TIMING BY MEASURING JITTER; QUALITY PROTOCOL SERVICES SUCH AS ATM, GR-313 AND 1 SDN; BULK PAYLOAD TESTING ON SDH CIRCUITS; VT100 EMULATION; DUAL PCMCIA SLOTS; BUILT-IN MICROPHONE AND SPEAKER
WIDTH 292.0 MILLIMETERS NOMINAL

Restrictions/Controls & Freight Information | NSN 6625-01-570-5560

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information