Product Details | OHMMETER

6625-01-619-8145 An instrument which measures electrical resistance and is calibrated in ohms or any multiple and/or submultiples thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. See also TEST SET, INSULATION BBEAKDOWN.

Part Alternates: ANICBE8340144 , SATURN ISO , SATURNISO, 6625-01-619-8145, 01-619-8145, 6625016198145, 016198145

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 2013170 01-619-8145

Cross Reference | NSN 6625-01-619-8145

Part Number Cage Code Manufacturer
ANICBE8340144 U7237 MINISTRY OF DEFENCE NAVY DEFENCE M NITIONS
SATURN ISO 4U744 FLUKE ELECTRONICS CORPORATION DBA FLUKE
SATURN ISO KH122 BSRIA LIMITED

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-01-619-8145

Technical Data | NSN 6625-01-619-8145

Characteristic Specifications
III INSTALLATION DESIGN HAND HELD
INDICATOR TYPE DIGITAL DISPLAY
DISPLAY TYPE LIQUID CRYSTAL
DISPLAY DIGIT QUANTITY 4
FREQUENCY RESPONSE RANGE 45.0 TO 400.0 HERTZ
POWER SOURCE INTERNAL
CIRCUIT CURRENT FOR WHICH DESIGNED DC
OPERATING VOLTAGE RATING IN VOLTS 40.0 DC MINIMUM AND
FREQUENCY RATING 45.0 HERTZ MINIMUM AND
STYLE DESIGNATOR RECTANGULAR SURFACE MTG
OVERALL HEIGHT 110.0 MILLIMETERS NOMINAL
OVERALL LENGTH 240.0 MILLIMETERS NOMINAL
OVERALL WIDTH 180.0 MILLIMETERS NOMINAL
PART NAME ASSIGNED BY CONTROLLING AGENCY INSULATION TESTER

Restrictions/Controls & Freight Information | NSN 6625-01-619-8145

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information