NSN 6630-01-234-6794 428605, 4451 QBCII, 4451QBCII
Product Details | CLINICAL CHEMISTRY ANALYZER
6630-01-234-6794 A microprocessor based instrument incorporating more than one method of analysis such as colorimetric and potentiometric/ION selective or kinetic enzyme. It may be either a stand-alone unit or modular in design. For instruments which have only one method of analysis see ANALYZER, as modified. Excludes all instruments which employ a chromatographic method of analysis.
Part Alternates: 428605, 4451 QBCII, 4451QBCII, 4465, 4466, 60148P, 6-0148P, 663002840000, 6630-0284-0000, 6630-01-234-6794, 01-234-6794, 6630012346794, 012346794
Instruments and Laboratory Equipment | Chemical Analysis Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 18 JUN 1986 | 01-234-6794 | 42054 ( ANALYZER, CLINICAL CHEMISTRY ) |
Demand History | NSN 6630-01-234-6794
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 428605 | 2011-04-119 | 12 | Poland |
Cross Reference | NSN 6630-01-234-6794
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 428605 | 22790 | BECTON, DICKINSON AND COMPANY DBA BD DIAGNOSTIC SYSTEM |
| 428605 | 4AZY5 | QBC DIAGNOSTICS, INC. |
| 4451 QBCII | 22790 | BECTON, DICKINSON AND COMPANY DBA BD DIAGNOSTIC SYSTEM |
| 4465 | 12717 | BECTON DICKINSON AND CO PRIMARY CARE DIAGNOSTICS DIV |
| 4466 | 12717 | BECTON DICKINSON AND CO PRIMARY CARE DIAGNOSTICS DIV |
| 6-0148P | 64616 | DEFENSE MEDICAL STANDARDIZATION BOARD |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6630-01-234-6794
Related Products | NSN 6630-01-234-6794
Technical Data | NSN 6630-01-234-6794
| Characteristic | Specifications |
|---|---|
| CURRENT TYPE | AC |
| VOLTAGE IN VOLTS | 120.0 AND 220.0 |
| FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| ACCESSORY COMPONENTS AND QUANTITY | ELECTRO-OPTICAL MAGNIFICATION READER 1; WORK STATION 1; VENOUS-BLOOD PIPETTER 1 |
| SUPPLEMENTARY FEATURES | CONT C/O TWO SEALED CALIBRATION CHECK TUBES; ONE VENOUS,ONE CAPILLARY; ONE PAIR FORCEPS; SPARE PIPETTER "O" RINGS AND GREASE,SPARE LAMPS FUSES,TWO THRUST PIVOTS,ONE 5/64 IN. HEX KEY AND TEST GUIDE; CAPABLE OF PERFORMING THE FOLLOWING QUANTITATIVE FUNCTIONS ON A CENTRIFUGAL BLOOD TUBE; HEMOGLOBIN,HEMATOCRIT,PLATELET COUNT,WHITE BLOOD COUNT,GRANULOCYTE COUNT,AND LYMPHOCYTE-MONOCYTE COUNT; FOR CAPILLARY MICROHEMATOCRIT TUBE KIT ORDER 6630-01-233-7594; FOR VENOUS MICROHEMATOCRIT TUBE KIT,ORDER 6630-01-233-7593 AND VENOUS HEMATOCRIT TUBE KIT 6630-01-233-9592; REQUISITIONER SHOULD SPECIFY THE VOLTAGE AND FREQUENCY REQUIRED |
| UNIT OF ISSUE WEIGHT | 30.00 POUNDS |
| EXTERIOR CONTAINER WEIGHT | 30.00 POUNDS |
| SPECIAL FEATURES | MICROPROCESSOR CONTROLLED ELECTRO-OPTICAL INSTRUMENT FOR MEASURING PACKED CELL VOLUMES AND CONVERTING TO RELATIVE VALUES;COMPONENTS INC.75X MONOCULAR MICROSCOPE,ROTATING TUBE CARTRIDGE ASSY;OPICAL ENCODER;UV ILLUMINATOR LAMP;VARIOUS LENSES AND FILTERS TO CAUSE STAINED WHITE CELLS AND PLATELETS TO FLUORESCE;12 PLACE HEMATOCRIT CENTRIFUGE WITH HEAD COVER,FIXED FIVE MINUTE TIMER;12,000 RPM SPEED CAPACITY;AND RCF OF 14,387 X G;TWO POSITION PIPETTER WITH FIXED VOLUME OF 111.1 MICROLITERS;WORK STATION WITH NUMBERED SLOTS FOR CAPILLARY TUBES;WELLS FOR WHOLE BLOOD TUBES AND RACK FOR STORAGE OF PIPETTER;OPERATION METHOD:ELECTRIC;EXTERIOR CONTAINER QUANTITY:1;THE NUMBER OF ALTERNATING CURRENT PHASE:TWO |
| III PART NAME ASSIGNED BY CONTROLLING AGENCY | ANALYZER CENTRIFUGAL HEMATOLOGY 120/220V 50/60HZ 216MM ID |
Restrictions/Controls & Freight Information | NSN 6630-01-234-6794
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 058280 | SCIENTIFIC INSTRUMENTS NOI |
| Less than car load rating | ||
| Less than truck load rating | D | 200.0 |
| Water commodity Code | 652 | unknown |
| Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | V | Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6630-01-234-6794
| Category | Code | Description |
|---|---|---|
| Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
| Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
| Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
| Specific Group/Generic Code | 0 | Medical Materiel |
| Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
| Accounting Requirements Code | N | Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DA | Department of the Army |
| Service Organization | A | U.S. Army |
| Reparability | O | If condemned or economically unserviceable, dispose at organizational level. |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
| Combat Essentiality Code | 3 | Critical for Health and Safety of Personnel. Those parts and components that are required for the health and safety of personnel, and which do not fit the definition of Code 5 or 6 items. |
| Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Physical Category Code | 1 | Bin |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |