Product Details | ELECTRIC WATER BATH

6640-00-062-7693 An item consisting of electric heating element(s) and a liquid reservoir, designed for use in the laboratory for making test(s), such as digestion, evaporation, sterilization and melting by means of heating specimens contained in beakers, flasks, test tubes and the like. Excludes WATER BATH, NONELECTRIC.

Part Alternates: 13330041, 13330-041, 15454A, 15-454A, 66566, 6640-00-062-7693, 00-062-7693, 6640000627693, 000627693

Instruments and Laboratory Equipment | Laboratory Equipment and Supplies

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 1963 00-062-7693

Cross Reference | NSN 6640-00-062-7693

Part Number Cage Code Manufacturer
13330-041 08455 UNIVAR CORP VAN WATERS AND ROGERS INC
15-454A 22527 FISHER SCIENTIFIC COMPANY L.L.C.
66566 48619 PRECISION SCIENTIFIC PETROLEUM INSTRUMENTS CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6640-00-062-7693

Technical Data | NSN 6640-00-062-7693

Characteristic Specifications
RESERVOIR MATERIAL STEEL, STAINLESS
SHAPE RECTANGULAR
INSIDE LENGTH 18.000 INCHES NOMINAL
INSIDE WIDTH 12.000 INCHES NOMINAL
INSIDE DEPTH 5.500 INCHES NOMINAL
RESERVOIR REMOVABILITY NONREMOVABLE
CONSTANT WATER LEVEL ATTACHMENT INCLUDED
LOW WATER CUTOFF NOT INCLUDED
TEST TUBE RACK NOT INCLUDED
HEATING ELEMENT QUANTITY 2
HEATING ELEMENT TYPE ELECTRIC IMMERSION
HEATING ELEMENT CURRENT TYPE AC
HEATING ELEMENT VOLTAGE RATING 115.0 VOLTS NOMINAL
HEATING ELEMENT WATTAGE IN WATTS 1000.0
AGITATOR NOT INCLUDED
OPERATING TEMP RANGE 20.0 TO 100.0 DEG CELSIUS
THERMOREGULATOR INCLUDED
ACCURACY RANGE -0.1 TO 0.1 DEG CELSIUS
TEMP REGULATING SETTINGS 37 DEG C AND 56 DEC C
COOLING COILS FOR BELOW ROOM TEMP USE NOT INCLUDED
MOUNTING TYPE ANY ACCEPTABLE
INSULATED FEATURE INCLUDED
THERMOMETER OPENING NOT PROVIDED
PILOT LIGHT INCLUDED

Restrictions/Controls & Freight Information | NSN 6640-00-062-7693

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information