NSN 6640-00-135-9644 R4138, 00-135-9644, 001359644
Product Details | LABORATORY SHAKING MACHINE
6640-00-135-9644 00001016640000000
Part Alternates: R4138, 6640-00-135-9644, 00-135-9644, 6640001359644, 001359644
Instruments and Laboratory Equipment | Laboratory Equipment and Supplies
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 15 JAN 1969 | 00-135-9644 | 13440 ( SHAKING MACHINE, LABORATORY0 ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6640-00-135-9644
Related Products | NSN 6640-00-135-9644
Technical Data | NSN 6640-00-135-9644
| Characteristic | Specifications |
|---|---|
| UNIT TYPE | ROTATING |
| HOLDER TYPE | PLATFORM |
| HOLDER CAPACITY | FOUR 3 IN. BY 2 IN. SEROLOGICAL SLIDES,EACH SLIDE W/12 14 MM ID CERAMIC RINGS |
| RATED SPEED | 180.0 REVOLUTIONS PER MINUTE |
| CURRENT TYPE | AC |
| VOLTAGE RATING | 115.0 VOLTS NOMINAL |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| POWER RATING | 50.0 WATTS NOMINAL |
| OVERALL LENGTH | 8.250 INCHES NOMINAL |
| OVERALL HEIGHT | 4.000 INCHES NOMINAL |
| OVERALL WIDTH | 8.750 INCHES NOMINAL |
| INTERVAL TIMER | INCLUDED |
| ACCESSORY COMPONENTS AND QUANTITY | THREE CONDUCTOR CABLE,6 FT LG 1 |
| SPECIAL FEATURES | W/COUNTER CAPABLE OF RECORDING FROM 000 TO 999 |
Restrictions/Controls & Freight Information | NSN 6640-00-135-9644
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 014500 | APPARATUS CHEMICAL LABORATORY |
| Less than car load rating | F | 150 |
| Less than truck load rating | F | 150.0 |
| Water commodity Code | 534 | unknown |
| Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | C | Chemical corps items and all other chemicals not covered in other classifications. When chemical item (as indicated by the DOT Proper Shipping Name) is sensitive as defined in Appendix A Section I of DoD 4500.32-R, Volume I, second position must be from table 85 , part 1. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6640-00-135-9644
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9L | Navy-owned stocks of defense medical material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | S9M | Defense Supply Center Philadelphia Director of Medical Materiel Philadelphia, PA 19145 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |