Product Details | LABORATORY CENTRIFUGE

6640-00-190-1853 A mechanical device using centrifugal force to separate liquids from solids, which might normally be held by them in suspension, or a liquid of one density from that of another.

Part Alternates: C15821, C1582-1, 8196, 6640-00-190-1853, 00-190-1853, 6640001901853, 001901853

Instruments and Laboratory Equipment | Laboratory Equipment and Supplies

Supply Group (FSG) NSN Assign. NIIN
66 03 MAR 1971 00-190-1853

Cross Reference | NSN 6640-00-190-1853

Part Number Cage Code Manufacturer
8196 30988 THERMO ELECTRON CORPORATION DBA IEC CENTRIFUGE DIV LABORATORY
C1582-1 07TA6 CARDINAL HEALTH 200, LLC
C1582-1 22353 BAXTER HEALTHCARE CORP BAXTER SCIENTIFIC PRODUCTS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6640-00-190-1853

Technical Data | NSN 6640-00-190-1853

Characteristic Specifications
SEPARATION UNIT TYPE TRUNNION
HEAD PLACE QUANTITY 8
PLACE CONTAINER SIZE 100 ML TUBE CAPACITY IN. EA PLACE
SAFETY CAP INCLUDED
MAXIMUM SPEED RATING IN RPM 6000.0
OPERATION METHOD ELECTRIC
CURRENT TYPE AC
VOLTAGE IN VOLTS 115.0
FREQUENCY RATING 50.000 HERTZ MINIMUM 60.000 HERTZ MAXIMUM
PHASE SINGLE
GUARD BOWL INCLUDED
INSIDE DIAMETER 23.000 INCHES NOMINAL
DEPTH 14.500 INCHES NOMINAL
OVERALL LENGTH 31.000 INCHES NOMINAL
OVERALL WIDTH 24.000 INCHES NOMINAL
OVERALL HEIGHT 41.000 INCHES NOMINAL
FURNISHED CONTROLS RELAY,PROTECTIVE
ACCESSORY COMPONENTS AND QUANTITY 8 NEOPRENE CUSHIONS,8 BRASS JACKETS,1 8 PLACE TRUNNION,8 TRUNNION RINGS

Restrictions/Controls & Freight Information | NSN 6640-00-190-1853

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 014500 APPARATUS CHEMICAL LABORATORY
Less than car load rating P 77.5
Less than truck load rating F 150.0
Water commodity Code 732 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable