6640-01-506-2262 An item consisting of a reservoir and a temperature control device. It utilizes a liquid media to heat or control samples used in laboratory testing of organic coatings, asphalt and petroleum products. It can also be used to verify the accuracy of temperature sensors or instruments. It may include such components and accessories as water jackets, heaters, cooling coils, circulating pumps, bombs, and racks. Excludes WATER BATH, ELECTRIC and WATER BATH, NONELECTRIC.

Part Alternates: EW1250110, EW-12501-10, 6640-01-506-2262, 01-506-2262, 6640015062262, 015062262

Instruments and Laboratory Equipment | Laboratory Equipment and Supplies

Supply Group (FSG) NSN Assign. NIIN
66 25 MAR 2003 01-506-2262

Cross Reference | NSN 6640-01-506-2262

Part Number Cage Code Manufacturer
EW-12501-10 05668 COLE-PARMER INSTRUMENT COMPANY DBA BARNANT DIVISION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6640-01-506-2262

Technical Data | NSN 6640-01-506-2262

Characteristic Specifications
SHAPE RECTANGULAR
CAPACITY RATING 12.0 LITERS NOMINAL
INSIDE LENGTH 11.500 INCHES NOMINAL
INSIDE WIDTH 12.750 INCHES NOMINAL
INSIDE DEPTH 6.000 INCHES NOMINAL
OVERALL LENGTH 18.750 INCHES
OVERALL WIDTH 14.000 INCHES
OVERALL HEIGHT 9.500 INCHES
TEST TUBE RACK NOT INCLUDED
MATERIAL STEEL, STAINLESS
HEATING ELEMENT QUANTITY 1
AGITATOR NOT INCLUDED
OPERATING TEMP RANGE 5 DEGREES ABOVE AMBIENT TO 100 DEGREES C
THERMOREGULATOR NOT INCLUDED
TEMP REGULATING SETTINGS FRONT PANEL CONTROLS
COOLING COILS FOR BELOW ROOM TEMP USE NOT INCLUDED
INSULATED FEATURE NOT INCLUDED
THERMOMETER OPENING PROVIDED
PILOT LIGHT NOT INCLUDED
ACCESSORY COMPONENTS AND QUANTITY FIVE FOOT CORD

Restrictions/Controls & Freight Information | NSN 6640-01-506-2262

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information