Product Details | RADIACMETER

6665-00-022-0810 An item specifically designed to detect and measure radioactive energy; indicates directly. It may or may not include the function of a radiac computer.

Part Alternates: 510601, 510-601, 55555510MA, 555-555-10MA, 6665-00-022-0810, 00-022-0810, 6665000220810, 000220810

Instruments and Laboratory Equipment | Hazard-Detecting Instruments and Apparatus

Supply Group (FSG) NSN Assign. NIIN
66 06 MAY 1967 00-022-0810

Cross Reference | NSN 6665-00-022-0810

Part Number Cage Code Manufacturer
510-601 63060 HEICO OHMITE LLC DBA OHMITE MFG CO INC
555-555-10MA 63060 HEICO OHMITE LLC DBA OHMITE MFG CO INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6665-00-022-0810

Technical Data | NSN 6665-00-022-0810

Characteristic Specifications
RADIATION TYPE AND FUNCTION GAMMA RAYS MEASURES X-RAYS MEASURES
RADIATION RANGE PER HOUR NOT RATED
COUNT RANGE PER MINUTE NOT RATED
ACCURACY IN PERCENT -5.0 TO 5.0 ALL RANGES
INPUT SENSITIVITY VOLTAGE RATING ANY ACCEPTABLE
ENERGY DEPENDENCE RATING 30.0 TO 400.0 KEV
INDICATOR TYPE METER
DETECTING ELEMENT TYPE IONIZATION CHAMBER
CURRENT TYPE AC
VOLTAGE IN VOLTS 105.0 130.0
PHASE SINGLE
FREQUENCY IN HERTZ 60.0
PORTABILITY NONPORTABLE
CASE MATERIAL ALUMINUM
CASE SURFACE TREATMENT ENAMELED
OVERALL LENGTH 8.000 INCHES NOMINAL
OVERALL WIDTH 7.000 INCHES NOMINAL
OVERALL HEIGHT 10.000 INCHES NOMINAL
MOUNTING METHOD TABLE

Restrictions/Controls & Freight Information | NSN 6665-00-022-0810

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:FMunitions List Item or Commerce Control List Item. Demilitarization required. Demilitarization Instructions to be furnished by the Item/Technical Manager.
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable