Product Details | CHEMICAL AGENT MONITOR

6665-01-603-9109 A hand held device used for monitoring of chemical agent contamination on personnel and/or equipment. It detects vapors of chemical agents and may be designed to discriminate between vapors or various agents.

Part Alternates: FIRSTDEFENDER RMX, FIRSTDEFENDERRMX, 785213300002 , 6665-01-603-9109, 01-603-9109, 6665016039109, 016039109

Instruments and Laboratory Equipment | Hazard-Detecting Instruments and Apparatus

Supply Group (FSG) NSN Assign. NIIN
66 21 MAR 2012 01-603-9109

Cross Reference | NSN 6665-01-603-9109

Part Number Cage Code Manufacturer
FIRSTDEFENDER RMX 5RZ49 THERMO FISHER SCIENTIFIC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6665-01-603-9109

Technical Data | NSN 6665-01-603-9109

Characteristic Specifications
OVERALL WIDTH 4.500 INCHES NOMINAL
SPECIAL FEATURES RAMAN INSTRUMENT FOR RAPID,ACCURATE IDENTIFICATION OF UNKNOWN CHEMICALS INCLUDING:EXPLOSIVES,TOXIC CHEMICALS,CHEMICAL WARFARE AGENTS,NARCOTICS,PRECURSORS,WHITE POWERS AND MORE,CAN BE USED WITH FIXED PROBE OR MOUNTED TO SELECT ROBOTS,EXTERNAL POWER SUPPLY:DC WALL ADAPTER 12V,1.25A,OPERATING TEMPERATURE :-20 DEGREES TO +40 DEGREES CELSIUS.ITEM IS 7.7 X 4.5 X 2.4 INCH,LASER OUTPUT:POWER ADJUSTABLE 75MW,125MW,250MW,BATTERY:REMOVABLE AND RECHARGEABLE LITHIUMION BATTERY OR 123A (EG SUREFIRE) BATTERIES>4 HR OPERATION
OVERALL LENGTH 7.700 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 6665-01-603-9109

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description