Product Details | RADIAC DETECTOR

6665-01-618-5318 A device consisting of a permanent or replaceable element which is sensitive to radioactivity or free nuclear particles, together with its associated circuits and housing. As a result of the incident ionizing radiation, it produces an electron pulse or current flow that can be interpeted by other components. Does not include meters or indicators. Excludes PROBE, RADIAC.

Part Alternates: ICAM , 6665-01-618-5318, 01-618-5318, 6665016185318, 016185318

Instruments and Laboratory Equipment | Hazard-Detecting Instruments and Apparatus

Supply Group (FSG) NSN Assign. NIIN
66 2013116 01-618-5318

Cross Reference | NSN 6665-01-618-5318

Part Number Cage Code Manufacturer
ICAM 96696 CANBERRA INDUSTRIES INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6665-01-618-5318

Technical Data | NSN 6665-01-618-5318

Characteristic Specifications
RADIATION TYPE AND FUNCTION ALPHA RAYS DETECTS AND
RADIATION ENERGY RATING 10.0 MILLIROENTGENS PER HOUR MINIMUM
DETECTING ELEMENT TYPE SOLID STATE
DETECTING ELEMENT DETACHABILITY INTEGRAL
PREAMPLIFIER INCLUDED
PHOTOMULTIPLIER NOT INCLUDED
CASE MATERIAL ANY ACCEPTABLE
CABLE NOT INCLUDED
CONNECTOR NOT INCLUDED
OVERALL LENGTH 6.700 INCHES NOMINAL
OVERALL WIDTH 9.600 INCHES NOMINAL
OVERALL HEIGHT 21.000 INCHES NOMINAL
III PART NAME ASSIGNED BY CONTROLLING AGENCY ICAM ALPHA/BETA AIR MONITOR

Restrictions/Controls & Freight Information | NSN 6665-01-618-5318

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information