Product Details | ACCELEROMETER CALIBRATOR

6680-00-403-7937 A device specifically designed to plot acceleration calibration curves. May be of either automatic or manual operation type.

Part Alternates: 2965C, 6680-00-403-7937, 00-403-7937, 6680004037937, 004037937

Instruments and Laboratory Equipment | Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments

Supply Group (FSG) NSN Assign. NIIN
66 25 JUL 1969 00-403-7937

Cross Reference | NSN 6680-00-403-7937

Part Number Cage Code Manufacturer
2965C 95411 MEGGITT - ORANGE COUNTY, INC. DBA FOREIGN PARENT IS MEGGITT PLC,

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6680-00-403-7937

Technical Data | NSN 6680-00-403-7937

Characteristic Specifications
GRAVITY UNIT RANGE 20.0 TO 10000.0
OVERALL LENGTH 9.000 INCHES NOMINAL
OVERALL WIDTH 17.000 INCHES NOMINAL
OVERALL HEIGHT 38.750 INCHES NOMINAL
MOUNTING CONFIGURATION THREE MOUNTING HOLES (17/32 INCH DIA.) ARE EQUALLY SPACED ON A 7-3/8 INCH BOLT CIRCLE
SPECIAL FEATURES SHOCK MOTION CALIBRATOR USED TO CALIBRATE PIEZOELECTRIC AND PIEZORESISTIVE ACCELEROMETERS, MEASURES SHOCK AND RESONANT FREQUENCIES, DESIGNED TO BE USED WITH 28350F SYSTEM AND 2270 ACCELERATION STANDARD BY ENDEVC0. CALIBRATOR IS EQUIPED WITH A LIGHT BEAM AND PHOTODIODE SWITCH WHICH PRODUCES AN ELECTRIC SIGNAL. CONSISTS OF ANVIL 14886, 20, 50, 100G WITH A PULSE DURATION OF 2 MILLISEC. ANVIL 14887, 500G PULSE 1 MILLISEC, ANVIL 14888, 1000G, 0.7 MILLISEC, ANVIL 14889-1, 5000G, 0.15 MILLISEC, ANVIL 14889-2, 10000G, 0.1 MILLISEC, WITH AN ACCURACY OF +/- 10 PERCENT.THREE STEEL BALLS, PLUMB BOB ASSEMBLY,BATTERY, ENDEVCO 28761 POWER SUPPLY, RESONANT FREQUENCY RANGE 2500/50000 HERTZ

Restrictions/Controls & Freight Information | NSN 6680-00-403-7937

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information