NSN 6685-00-596-8765 T21001, T2100-1, 19V3107
Product Details | CAPILLARY TUBE AND BULB INDICATING THERMOMETER
6685-00-596-8765 A thermometer which employs a confined substance, whose measurable physical properties or one of them varies with a change in temperatrue and this energy transmitted into mechanical movement to indicate the temperature. For indoor/outdoor application, see THERMOMETER, SELF-INDICATING, LIQUID IN GLASS.
Part Alternates: T21001, T2100-1, 19V3107, 19V3-107, 6685-00-596-8765, 00-596-8765, 6685005968765, 005968765
Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 11 JAN 1975 | 00-596-8765 | 07419 ( THERMOMETER, INDICATING, CAPILLARY TUBE AND BULB ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6685-00-596-8765
Related Products | NSN 6685-00-596-8765
Technical Data | NSN 6685-00-596-8765
| Characteristic | Specifications |
|---|---|
| DIAL DIAMETER | 3.500 INCHES NOMINAL |
| BULB TYPE | FLEXIBLE CAPILLARY |
| BULB QUANTITY | 1 |
| ACTIVE PORTION LENGTH | 120.000 INCHES NOMINAL |
| BULB CONNECTION TYPE | THREADED |
Restrictions/Controls & Freight Information | NSN 6685-00-596-8765
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 058360 | THERMOMETERS,O/THAN CLINICAL |
| Less than car load rating | J | 100.2 |
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 652 | unknown |
| Originating Activity Code | SE | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |



