Product Details | PYROMETER AND THERMOCOUPLE TESTER

6685-01-010-8477 An instrument used for checking thermocouples and pyrometers. It is designed with a compensator which can be adjusted so that the measured electromotive force, corrected to a standard reference temperature, can be read directly from a scale. It can be used as a pH meter. Excludes RESISTOR, VARIABLE, WIRE WOUND; RESISTOR, VARIABLE, NONWIRE WOUND; METER, HYDROGEN ION TEST; and PYROMETER (as modified).

Part Alternates: DS350T3MJ201TSCAL, DS-350-T3-M-J201-TS-CAL, 6685-01-010-8477, 01-010-8477, 6685010108477, 010108477

Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Supply Group (FSG) NSN Assign. NIIN
66 08 OCT 1975 01-010-8477

Cross Reference | NSN 6685-01-010-8477

Part Number Cage Code Manufacturer
DS-350-T3-M-J201-TS-CAL 30072 EMERSON ELECTRIC CO DORIC SCIENTIFIC DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6685-01-010-8477

Technical Data | NSN 6685-01-010-8477

Characteristic Specifications
SCALE RANGE 0.0 TO 1600.0 DEG FAHRENHEIT
OVERALL LENGTH 15.000 INCHES NOMINAL
OVERALL WIDTH 8.500 INCHES NOMINAL
OVERALL HEIGHT 3.000 INCHES NOMINAL
SPECIAL FEATURES IRON CONSTANTAN THERMOCOUPLE
III SUPPLEMENTARY FEATURES MANUFACUTRERS NAME: CALIBRATOR,THERMOCOUPLE

Restrictions/Controls & Freight Information | NSN 6685-01-010-8477

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information