Product Details | SELF-INDICATING THERMOMETER

6685-01-236-3495 An item that has confined liquid whose physical property(ies) changes with variation in temperature and indicates the temperature to a division or number on a graduated scale(s). May include flexible tubing (capillary) for indoor/outdoor applications. Excludes: THERMOMETER, CLINICAL, HUMAN.20365150057Medical and Surgical Instruments, Equipment, and Supplies66600040Meteorological Instruments and Apparatus66850073Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Part Alternates: 115C67, 115C-67, 9322B10, 9322-B10, 6685-01-236-3495, 01-236-3495, 6685012363495, 012363495

Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Supply Group (FSG) NSN Assign. NIIN
66 16 JUL 1986 01-236-3495

Drawings & Photos | NSN 6685-01-236-3495


Cross Reference | NSN 6685-01-236-3495

Part Number Cage Code Manufacturer
115C-67 81346 AMERICAN SOCIETY FOR TESTING AND MATERIALS
9322-B10 59728 THOMAS, ARTHUR H CO (INC)

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6685-01-236-3495

Technical Data | NSN 6685-01-236-3495

Characteristic Specifications
SCALE TYPE ENCLOSED GLASS
SCALE MEASUREMENT RANGE 0.000 TO 5.400 DEG CELSIUS AND 10.000 TO 140.000 DEG CELSIUS
STYLE DESIGNATOR A30 CYLINDRICAL CASE, STRAIGHT ANGLE
SPECIAL FEATURES MERCURY INDICATING FLUID

Restrictions/Controls & Freight Information | NSN 6685-01-236-3495

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information