Product Details | THERMOMETER CALIBRATOR

6685-01-241-5756 An item specifically designed to determine by comparison the accuracy of calibration of thermometers.

Part Alternates: M17673, M-17673, YSIM17673, YSI-M-17673, 6685-01-241-5756, 01-241-5756, 6685012415756, 012415756

Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Supply Group (FSG) NSN Assign. NIIN
66 28 SEP 1986 01-241-5756

Cross Reference | NSN 6685-01-241-5756

Part Number Cage Code Manufacturer
M-17673 97794 YSI INCORPORATED DBA YELLOW SPRINGS INTERNATIONAL
YSI-M-17673 97794 YSI INCORPORATED DBA YELLOW SPRINGS INTERNATIONAL

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6685-01-241-5756

Technical Data | NSN 6685-01-241-5756

Characteristic Specifications
CALIBRATION TYPE DEG CELSIUS
INSTRUMENT CALIBRATION RANGE SILVER FREEZE TEMP. 961.83 DEG C
OVERALL LENGTH 9.750 INCHES NOMINAL
OVERALL DIAMETER 2.000 INCHES NOMINAL
SHAPE RECTANGULAR
SPECIAL FEATURES ITEM INCLUDES A WELL FOR THE THERMOMETER UNDER TEST; QUARTZ SEALED ENVELOPE; IT CONTAINS AN INERT GAS AT A PRESSURE OF 1 STANDARD ATMOSPHERE AT THE FREEZING TEMPERATURE
III SUPPLEMENTARY FEATURES MANUFACTURERS NAME: FIXED POINT REFERENCE CELL
III FUNCTIONAL DESCRIPTION USES DEFINING AND REFERENCE FIXED POINTS BASED ON THE FREEZING TEMP OF METALS TO CALIBRATE THERMOMETERS

Restrictions/Controls & Freight Information | NSN 6685-01-241-5756

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information