Product Details | THERMOWELL

6685-01-267-9982 A pressure-tight receptacle mounted to an item by external threads, flange and/or welding. It is designed to hold temperature sensing devices, such as, termocouples, resistance temperature detectors, and thermometers.

Part Alternates: 223242, 223-242, 6685-01-267-9982, 01-267-9982, 6685012679982, 012679982

Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Supply Group (FSG) NSN Assign. NIIN
66 21 NOV 1987 01-267-9982

Demand History | NSN 6685-01-267-9982

Part Number Request Date QTY Origin
223242 2023-04-106 17 DIBBS
223242 2022-07-182 71 DIBBS
223242 2022-06-173 14 DIBBS
223242 2022-06-167 71 DIBBS
223242 2022-02-48 45 DIBBS
223242 2021-11-322 13 DIBBS
223242 2021-06-174 13 DIBBS
223242 2021-03-80 20 DIBBS
6685-01-267-9982 2017-05-129 258 DIBBS
6685-01-267-9982 2017-01-04 62 DIBBS
6685-01-267-9982 2013-09-252 93 DIBBS
6685-01-267-9982 2012-05-151 81 DIBBS
6685-01-267-9982 2011-07-188 64 DIBBS
6685-01-267-9982 2009-03-76 58 DIBBS

Cross Reference | NSN 6685-01-267-9982

Part Number Cage Code Manufacturer
223-242 19857 ELECTRIC HEATER COMPANY, THE DBA HUBBELL-ELECTRIC HEATER CO
223242 19278 DETROIT SWITCH, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6685-01-267-9982

Technical Data | NSN 6685-01-267-9982

Characteristic Specifications
MATERIAL BRASS

Restrictions/Controls & Freight Information | NSN 6685-01-267-9982

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 058360 THERMOMETERS,O/THAN CLINICAL
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 651 unknown
Originating Activity Code ZA Australia
ZB
ZC
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity E Engineer supplies, other than those listed under code B.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6685-01-267-9982

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each