Product Details | PRESSURE TRANSMITTER

6685-01-467-8789 An instrument that senses, measures and converts pressure of a gas or fluid into electrical signals to be displayed in Pounds per Square Inch (PSI) or the equivalent. The item contains an input pressure port, electrical output connection and may include an output pressure port. See also TRANSDUCER, MOTIONAL PICKUP for items with a linear motional input and electrical output to be displayed in other than PSI or the equivalent.20266200018Engine Instruments66850073Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Part Alternates: 1501671D, 6685-01-467-8789, 01-467-8789, 6685014678789, 014678789

Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Supply Group (FSG) NSN Assign. NIIN
66 17 SEP 1999 01-467-8789

Cross Reference | NSN 6685-01-467-8789

Part Number Cage Code Manufacturer
1501671D 33955 TELEFLEX INC ELECTRICAL SYSTEMS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6685-01-467-8789

Technical Data | NSN 6685-01-467-8789

Characteristic Specifications
CONTACT QUANTITY 1
CONTACT TYPE BINDING NUT
ELECTRICAL CONNECTION CONTROLLING AGENCY TELEFLEX INC
ELECTRICAL CONNECTION IDENTIFYING NUMBER 1501671D
ACTUATION METHOD PRESSURE SENSITIVE CAPSULE
MEASUREMENT RANGE -40.0 TO 320.0 DEG FAHRENHEIT
OVERALL LENGTH 3.600 INCHES NOMINAL
OVERALL DIAMETER 2.070 INCHES NOMINAL
III END ITEM IDENTIFICATION HEAVY EQPT SUP. VEH. (HESV),WESTERN STAR TRUCKS INC

Restrictions/Controls & Freight Information | NSN 6685-01-467-8789

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information