Product Details | SELF-INDICATING THERMOMETER

6685-01-526-1671 An item that has confined liquid whose physical property(ies) changes with variation in temperature and indicates the temperature to a division or number on a graduated scale(s). May include flexible tubing (capillary) for indoor/outdoor applications. Excludes: THERMOMETER, CLINICAL, HUMAN.20365150057Medical and Surgical Instruments, Equipment, and Supplies66600040Meteorological Instruments and Apparatus66850073Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Part Alternates: PCD41500150110, PCD4150015-0110, 6685-01-526-1671, 01-526-1671, 6685015261671, 015261671

Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Supply Group (FSG) NSN Assign. NIIN
66 09 DEC 2004 01-526-1671

Demand History | NSN 6685-01-526-1671

Part Number Request Date QTY Origin
PCD41500150110 2014-09-254 2 Canada

Cross Reference | NSN 6685-01-526-1671

Part Number Cage Code Manufacturer
PCD4150015-0110 50237 CAE USA INC. DBA CAE USA SIMULATION PRODUCTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6685-01-526-1671

Technical Data | NSN 6685-01-526-1671

Characteristic Specifications
SPECIAL FEATURES REFERENCE CAE USA PARTS CATALOG 116-PC-001; THERMOMETER DESIGNATED 110 DEGF
III END ITEM IDENTIFICATION FLIGHT SIMULATOR, CAE USA, MODEL RAN SH-2G (A)

Restrictions/Controls & Freight Information | NSN 6685-01-526-1671

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information