NSN 6685-01-542-3818 EWSRH, EWS-RH, 01-542-3818
Product Details | HUMIDITY-TEMPERATURE RECORDING CONTROL
6685-01-542-3818 A device composed of sensing elements, one or more switches, a control-actuating mechanism, and a graduated chart, for automatically controlling and recording humidity and temperature in assembly rooms, buildings, compartments, laboratories, and the like. May have a thermometer or other indicator(s).
Part Alternates: EWSRH, EWS-RH, 6685-01-542-3818, 01-542-3818, 6685015423818, 015423818
Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | 02 AUG 2006 | 01-542-3818 | 05663 ( CONTROL, HUMIDITY-TEMPERATURE RECORDING ) |
Cross Reference | NSN 6685-01-542-3818
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| EWS-RH | 29907 | OMEGA ENGINEERING, INC. |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6685-01-542-3818
Related Products | NSN 6685-01-542-3818
Technical Data | NSN 6685-01-542-3818
| Characteristic | Specifications |
|---|---|
| POWER SOURCE | EXTERNAL |
| MAXIMUM VOLTAGE RATING IN VOLTS | 5.0 DC |
| INDICATION METHOD | TRANSMITTING ELECTRICAL DIGITAL DISPLAY |
| CASE MATERIAL | PLASTIC |
| INCLOSURE TYPE | ENCASED |
| MAXIMUM OVERALL LENGTH | 79.000 INCHES |
| MAXIMUM OVERALL WIDTH | 54.000 INCHES |
| MAXIMUM OVERALL HEIGHT | 45.000 INCHES |
| OPERATING TEMP RANGE | 5.0 TO 140.0 DEG FAHRENHEIT |
| MOUNTING METHOD | WALL OR CONDUIT |
| OPERATING RANGE | HUMIDITY 5 - 95 % (NON-CONDENSING) |
Restrictions/Controls & Freight Information | NSN 6685-01-542-3818
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||