Product Details | PRESSURE TRANSMITTER

6685-01-591-4194 An instrument that senses, measures and converts pressure of a gas or fluid into electrical signals to be displayed in Pounds per Square Inch (PSI) or the equivalent. The item contains an input pressure port, electrical output connection and may include an output pressure port. See also TRANSDUCER, MOTIONAL PICKUP for items with a linear motional input and electrical output to be displayed in other than PSI or the equivalent.20266200018Engine Instruments66850073Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Part Alternates: ETM375350BARA, ETM-375-350BAR-A, 6685-01-591-4194, 01-591-4194, 6685015914194, 015914194

Instruments and Laboratory Equipment | Pressure, Temperature, and Humidity Measuring and Controlling Instruments

Supply Group (FSG) NSN Assign. NIIN
66 25 JAN 2011 01-591-4194

Cross Reference | NSN 6685-01-591-4194

Part Number Cage Code Manufacturer
ETM-375-350BAR-A 34345 KULITE SEMICONDUCTOR PRODUCTS, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6685-01-591-4194

Technical Data | NSN 6685-01-591-4194

Characteristic Specifications
SPECIAL FEATURES 4 CONDUCTOR 30AWG SHIELDED CABLE; OP TEMP: -55 DEG TO +120 DEG C; PRESSURE RANGE: 0 TO 35 BAR; 316 STAINLESS STEEL; PRESSURE MEDIA: ANY LIQUID OR GAS COMPATIBLE WITH 15-5 PLT OR 316 STAINLESS STEEL
OVERALL LENGTH 36.000 INCHES NOMINAL
PART NAME ASSIGNED BY CONTROLLING AGENCY 5 VDC OUTPUT IS PRESSURE TRANSDUCER
CURRENT TYPE DC

Restrictions/Controls & Freight Information | NSN 6685-01-591-4194

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information