Product Details | DISPLAY UNIT

7025-01-621-8951 An indicator unit on which computer information is visually displayed. Indication of data may be achieved by cathode ray tubes, plasma display, light emitting diodes, crystal display or the like. For items which also include an input section such as a keyboard, cursor, or rolling ball, see TERMINAL, DATA PROCESSING.

Part Alternates: VT121XA, VT121XARMD100000RL, VT121XA-RM-D-1-0-0-0-0-0-RL , 401-200-200 , 7025-01-621-8951, 01-621-8951, 7025016218951, 401200200, 016218951

Automatic Data Processing Equipment (Including Firmware), Software, Supplies and Support Equipment | ADP Input/Output and Storage Devices

Supply Group (FSG) NSN Assign. NIIN
70 2013263 01-621-8951

Cross Reference | NSN 7025-01-621-8951

Part Number Cage Code Manufacturer
401-200-200 Z1V65 L-3 COMMUNICATIONS OCEANIA PTY LTD
VT121XA 0ZE75 VARTECH SYSTEMS
VT121XA-RM-D-1-0-0-0-0-0-RL 0ZE75 VARTECH SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 7025-01-621-8951

Technical Data | NSN 7025-01-621-8951

Characteristic Specifications
DISPLAY TYPE LIGHT EMITTING DIODE
DIAGONAL DISPLAY SIZE IN INCHES 12.1
VOLTAGE IN VOLTS AND CURRENT TYPE 9.0 DC AND
OPERATING TEMP RANGE -20.0 TO 70.0 DEG CELSIUS
SPECIAL FEATURES BLACK ANODIZED ALUMINUM ENCLOSURE WITH CORROSION PROTECTION; STORAGE TEMPERATURE: -40 DEG C TO +75 DEG C; HIGH RESOLUTION IS EQUIPPED WITH VARTECH'S PROPRIETARY ENHANCED LIGHT TRANSMISSION TECHNOLOGY (ELTT)
PART NAME ASSIGNED BY CONTROLLING AGENCY ALL-WEATHER, ALL-TERRAIN FULLY SEALED IP68 (NEMA 6P) SUBMERSIBLE EXTREME OPERATIONAL TEMPERATURE SUNLIGHT READABLE LCD

Restrictions/Controls & Freight Information | NSN 7025-01-621-8951

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information