Product Details | OBSERVATION WINDOW

9340-01-029-6012 A transparent item of a predetermined size that permits unobstructed and undistorted view of a desired area. It may include a frame, have reference markings, grid lines and may be heat strengthened and/or tinted. It is generally used where safety, security, and/or the restriction of foreign matter are required, such as the visual examination of the inside of pressurized tanks, liquid sights, controlled liquid flow, and inspection of equipment enclosed in a housing. See WINDOW (as modified); SCALE, CATHODE RAY TUBE; SCALE, PLOTTING; WINDOW, METAL; WINDOW, WOOD; and WINDOW PANEL, AIRCRAFT.20293300029Plastics Fabricated Materials93400026Glass Fabricated Materials

Part Alternates: 1005423, 9340-01-029-6012, 01-029-6012, 9340010296012, 010296012

Nonmetallic Fabricated Materials | Glass Fabricated Materials

Supply Group (FSG) NSN Assign. NIIN
93 18 OCT 1976 01-029-6012

Drawings & Photos | NSN 9340-01-029-6012


Cross Reference | NSN 9340-01-029-6012

Part Number Cage Code Manufacturer
1005423 95750 AERONAUTICAL INSTRUMENT AND RADIO COMPANY, THE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 9340-01-029-6012

Technical Data | NSN 9340-01-029-6012

Characteristic Specifications
STYLE DESIGNATOR 1 SQUARE CORNERS
OVERALL LENGTH 4.500 INCHES NOMINAL
OVERALL WIDTH 1.620 INCHES NOMINAL
OVERALL THICKNESS 0.250 INCHES NOMINAL
MATERIAL PLASTIC
MATERIAL DOCUMENT AND CLASSIFICATION HOMALITE NO. 911 MFR REF SINGLE MATERIAL RESPONSE
MATERIAL TRANSPARENCY CLEAR
TEMP AT MAXIMUM OPERATING PRESSURE NOT RATED
MAXIMUM OPERATING PRESSURE NOT RATED
HARDNESS RATING NOT RATED
MINIMUM TENSILE STRENGTH NOT RATED
RADIATION PROTECTION RATING NOT RATED
III END ITEM IDENTIFICATION 6625000090846

Restrictions/Controls & Freight Information | NSN 9340-01-029-6012

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 086940 GLASS WINDOW O/T PLATE
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 704 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable